Setup
14
3A1602H
Lock/Unlock Handle
Lock the handle when the sprayer is moved, laid on its
side, or turned upside down.
Unlock
To unlock the handle, remove lanyard and locking pin
from cart handle. Pull on handle to extend cart handle
and move sprayer.
Lock
To lock the handle, press down handle pins and slide
cart handle through tubes. Insert pin through cart handle
and lock with lanyard.
Install 38 mm Spout Adapter
The sprayer is supplied with a 40 mm spout adapter.
Install 38 mm spout adapters if necessary.
1.
Loosen containment knob.
2.
Remove suction tube caps and place in contain-
ment tray.
3.
For installation instructions, see
Spout Adapter
,
page 45.
Install Desiccant Dryers
1.
Use needle nose pliers to remove two plugs (P)
from the dryer (73).
2.
Remove plug from adapter housing (57).
3.
Screw the dryer into the adapter housing (57) hand-
tight only. Do not overtighten.
F
IG
. 3
F
IG
. 4
ti17513a
ti17514a
F
IG
. 5: Spout Adapters
F
IG
. 6: Desiccant Dryer Installation
ti18063a
Black
Silver
40 mm
38 mm
ti17475a
P
P
57
73
Содержание Reactor E-8p 3A1602H
Страница 16: ...Setup 16 3A1602H 12 Install fluid tubes 36...
Страница 36: ...Repair 36 3A1602H FIG 56 Function Knob Potentiometer ti17465a 10 61 12 16a 23 22 87 16 N S P...
Страница 40: ...Repair 40 3A1602H FIG 59 Pressure Transducer Connection 35 ti17467a 33...