Reactor 2 E-XP2i
All base systems include fluid inlet pressure and temperature sensors and Graco InSite
™
. For part numbers,
see
.
No Air Compressor/Dryer
With Air Compressor/Dryer
Model
E-XP2i with heat
E-XP2i with heat
Base Machine
272081
272091
Maximum Fluid Working Pressure psi
(MPa, bar)
3500 (24.1, 241)
3500 (24.1, 241)
Approximate Output per Cycle (A+B)
gal. (liter)
0.0203 (0.0771)
0.0203 (0.0771)
Max Flow Rate gal/min (l/min)
2.0 (7.6)
2.0 (7.6)
Total System Load † (Watts)
11,600
17,700
Voltage (phase)
240 VAC (1)
240 VAC (1)
Available Auxiliary Current at Volts, 60
Hz*
35 Amps (240)
5 Amps (240)
9 Amps (120)
Fusion AP Package
(Gun Part No.)
AP2081
(246101)
AP2091
(246101)
Probler P2 Package
(Gun Part No.)
P22081
(GCP2R1)
P22091
(GCP2R1)
Heated Hose
50 ft (15 m)
24Y241
24Y241
Heated Whip Hose
10 ft (3 m)
246055
246055
Total system watts used by system, based on
maximum heated hose length of 310 ft (94.5 m)
for each unit.
*
Full load amps available for auxiliary equipment
when all bare-system components are operating
at maximum capabilities. Available auxiliary
current is based on 310 ft (94.5 m) of heated hose.
An additional 3.0 amps (240 VAC) of auxiliary
current is available for each 50 ft (15.2 m) section
of heated hose that is not used.
Auxiliary current at 120 VAC is available on line 1
(circuit breaker pin 2), line 2 current at 120 VAC is
used by the air dryer (circuit breaker pin 4).
Available auxiliary current will be less when the
engine is de-rated for site altitude. Reduce the
Available Auxiliary Current in the chart by 2.5
Amps (240 VAC) per 1000 ft (300 m) elevation
increments. If the available auxiliary current is
less than zero, the system configuration may not
support the full load at that altitude.
Includes Complete Air Compressor/Dryer Kit
24U176.
Refer to
Circuit Breaker Configuration Options,
.
See
.
Packages include gun, heated hose, and whip
hose.
332636C
11