Startup
64
313997A
The weight calibration procedure is now complete.
Repeat this procedure when changing materials, if
material viscosity or specific gravity changes signifi-
cantly, or if the operating parameters of the system are
modified (orifice size, temperature setpoints, etc.).
3.
Set temperatures (Heated models only)
For detailed temperature adjustments, including alarm
levels, or upon initial machine configuration, see Condi-
tioning Screen 2 on page 48 for details. For minor
adjustments to the temperature setpoint once the
machine has been initially configured, see the Status
Screen on page 54.
4.
Set system control and dispense modes: See
System Screen 1 on page 43.
5.
Set pump sizes: See System Screen 1 on
page 43.
6.
Define Shot Recipes
a.
Navigate to the Shots screen.
b.
Press
to enter the screen.
c.
Use the directional keypad to navigate to the
shot detail column for the desired shot number.
d.
Type the desired setting for that item then
press
.
e.
Repeat the previous two steps for all desired
shot numbers.
7.
Change pressure imbalance setting (optional)
The pressure imbalance function detects conditions that
can cause off-ratio dispense, such as loss of feed pres-
sure/supply, pump seal failure, clogged fluid inlet filter, or
a fluid leak.
The pressure imbalance default is factory-set at 500 psi
(3.5 MPa, 35 bar). For tighter ratio error detection, select
a lower value. For looser detection or to avoid nuisance
alarms, input a higher value.
a.
Navigate to System Screen 3.
b.
Press
to enter the screen.
c.
Navigate to the pressure imbalance field.
d.
Type the desired pressure imbalance setting
then press Enter
.
This equipment is used with heated fluid, which can
cause equipment surfaces to become very hot. To
avoid severe burns:
•
Do not touch hot fluid or equipment.
•
Allow equipment to cool completely before touch-
ing it.
•
Wear gloves if fluid temperature exceeds 110°F
(43°C).