Setup Screens
48
313997A
Conditioning Screen 2
This screen shows the fluid path for the temperature
conditioning components and temperature setpoints for
each component.
To edit the temperature setpoint and alarms for a partic-
ular component:
1.
Press the Enter Screen button and navigate to the
component you wish to edit.
2.
Press the enter key to display the setpoint and
alarm values associated with that component.
3.
Edit the setpoint and alarm values and then press
the page back button to return to the previous
screen.
Conditioning Screen 3
This page allows the user to configure Night Mode
operation. In Night Mode, the system will cycle on and
off periodically. Press the Enter Screen button and
adjust the on and off durations as desired.
When the system is in Night Mode and in an on
duration, the system will circulate in low pressure. The
installed conditioning zones will be on and controlling to
their respective setpoints. When the system is in Night
Mode and in an off duration, the system will be idle.
The system will not be circulating, and the conditioning
zones will not be actively controlling temperature.
NOTE: Gray fields on this screen are not available at
this time. Future product releases will incorporate these
features.
Advanced Screen 1
This screen allows the user to set the language, date
format, current date, time, setup screens password,
screen saver delay, and turn on or off silent mode.
Advanced Screen 2
This screen allows the user to set the units of measure.