Setup Screens
313997A
47
•
The low level alarm and the high level deviation will
clear when the condition clears.
•
A button is provided to the user on the Run screens
to instigate an automatic refill operation at any time.
This button can also be used to abort a refill opera-
tion.
The refill time-out setting may be set by the user as a
means to abort the dispense in the case of a high level
sensor failure. When an automatic refill begins, the
time-out counter will begin to count down. If the timer
expires before the high level sensor is satisfied, the refill
will abort. Setting the refill time-out to a value of 0 will
disable the feature.
Conditioning Screen 1
This screen allows the user to select which temperature
conditioning components are installed in the system.
Check the box next to the component type for the appro-
priate side of the system to indicate that a component is
installed. A maximum of four components may be
selected.
Icon
Function
Tank Blanket Heater
Primary Heater
Heated Hose
Chiller