Setup
313997A
33
Setup
Perform this setup procedure to secure all necessary
machine connections for machine operation.
1.
Locate HFR.
a.
Locate HFR on a level surface. See Dimen-
sions on page 95 for space requirements.
b.
Do not expose HFR to rain.
2.
Electrical requirements. See Models on page 4
for detailed electrical requirements information.
3.
Connect electrical cord.
NOTE:
Power cord is not supplied. See the following table.
† Residual Current Device (RCD) must be rated at
300 mA if installed.
Electrical Cord Wires by Model
230V, 1 phase: L1, L2, GND
230V, 3 phase: L1, L2, L3, GND
400V, 1 phase: L1, L2, L3, N, GND
Use 5/32 or 4 mm hex allen wrench to connect the two
or three power leads to L1, L2, and L3, as applicable.
Connect green to ground (GND).
NOTICE
Bolt HFR to original shipping pallet before lifting.
Installing this equipment requires access to parts
which may cause electric shock or other serious injury
if work is not performed properly. Have a qualified
electrician connect power and ground to main power
switch terminals, see step 3 in this setup procedure.
All electrical wiring must be done by a qualified electri-
cian and comply with all local codes and regulations.
Table 1: Power Cord Requirements
Model
Cord Requirements
AWG (mm
2
)
Non-Heated HFR,
230V, 1 phase
4 (21.2), 2 wire + ground
Non-Heated HFR,
230V, 3 phase
6 (13.3), 3 wire + ground
Non-Heated HFR,
400V, 3 phase
4 (21.2), 4 wire + ground †
Heated HFR,
230V, 1 phase
1 (42.4), 2 wire + ground
Heated HFR,
230V, 3 phase
4 (21.2), 3 wire + ground
Heated HFR,
400V, 3 phase
4 (21.2), 4 wire + ground †
F
IG
. 12: 400V, 1 phase shown
r_24C686_313998_1a
L1
L2
L3
N
GND