Setup Screens
46
313997A
Maintenance Screen
This screen shows shot number and sequence position
counters.
This screen shows shot number and sequence position
counters. Press the Enter Screen button and navigate to
the drop down box. Press the enter key and scroll to a
range of counters to view. Press the enter key again to
select the range of counters and display them on the
screen.
Counters may be erased individually. Navigate to the
counter you want to erase and press the Erase Individ-
ual button. Alternatively, each counter displayed on the
page may be erased simultaneously by pressing the
Erase All button.
Supply Screen
This screen allows the user to specify the operating
parameters for off-board, integrated tanks and indicate
which positions have level sensors installed. The user
may select from the following refill settings.
•
Disabled: Selected when off-board tanks are not a
part of the system or when the user wishes to dis-
able tank operation.
•
Monitor: The top sensor generates a high level
deviation and the bottom sensor generates a low
level alarm. Automatic refill is not supported. No but-
ton is provided on the run screens to initiate an
automatic refill. Errors will clear when the corre-
sponding condition clears.
•
Manual: The low level sensor will generate a low
level alarm. A button is provided to the user on the
run screens to instigate an automatic refill operation
at any time. Automatic refill will run until either the
high level sensor is satisfied, the user aborts the
refill via the refill button on the run screens, or the
refill time-out expires. The low level alarm will clear
when the condition clears.
•
Auto Top-Off: The low level sensor will generate a
low level alarm. When the high level sensor is not
satisfied, automatic refill will begin and continue
until either the high level sensor is satisfied or until
the refill time-out expires. The low level alarm will
clear when the condition clears. A button is provided
to the user on the run screens to instigate an auto-
matic refill operation at any time. This button can
also be used to abort a refill operation.
•
Auto Full-Volume: The low level sensor will insti-
gate an automatic refill. Automatic refill will continue
until either the high level sensor is satisfied or until
the refill time-out expires. The low level alarm will
clear when the condition clears. A button is provided
to the user on the run screens to instigate an auto-
matic refill operation at any time. This button can
also be used to abort a refill operation.
If a refill setting other than Disabled is selected, the user
must set at least two level sensor locations to installed
(check the check box on the screen). If all three loca-
tions are set to installed, the system will default to the
Auto-Top Off refill setting and operate as follows:
•
The low level sensor will generate a low level alarm.
•
The high level sensor will generate a high level devi-
ation and abort any automatic refill operation.
•
When the middle sensor is not satisfied, automatic
refill will begin and will run until either the middle
sensor is satisfied, the high level sensor generates a
deviation (if the middle sensor fails), or the refill
time-out expires.
Icon
Function
Sequence Position
Shot Number
Erase Individual Counter
Erase All Counters on Page