Motor Control Module Technical Data
94
313997A
Motor Control Module Technical Data
Overtemperature protection is provided to protect from motor overload.
Current limit, set via the software, is provided as a secondary protection from motor overload.
All installations and wiring must comply with NEC and local electrical codes.
Input Specifications
Input Line Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . .
0-264 Vac, line-to-line
Input Line Phasing . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single or Three Phase
Input Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . .
50/60 Hz
Input Current per Phase . . . . . . . . . . . . . . . . . . . . . .
25A (three-phase), 50A (single-phase)
Maximum Branch Circuit Protection Rating: . . . . . . .
30A (three-phase), 63A (single-phase)
Short Circuit Current Rating . . . . . . . . . . . . . . . . . . .
5 kA
Output Specifications
Output Line Voltage . . . . . . . . . . . . . . . . . . . . . . . . . .
0-264 Vac
Output Line Phasing . . . . . . . . . . . . . . . . . . . . . . . . .
Three Phase
Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0-30A
Output Overload . . . . . . . . . . . . . . . . . . . . . . . . . . . .
200% for 0.2 seconds
DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24 Vdc, Class 2, Graco-provided power supply
Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type 1
Max Ambient Temperature . . . . . . . . . . . . . . . . . . . . . . . .
50°C (122°F)