Shutdown
313997A
65
Shutdown
1.
Park pumps.
a.
From the Home screen, press
and select
Standby mode.
b.
Press
. Material will dispense. Pump will
park automatically. Once pump is parked, pump
will stop moving.
If a dispense gun with a trigger is installed,
pulling the trigger will begin a park operation.
Material will dispense. Continue pulling the trig-
ger until the pump stops moving.
2.
Press the enable/disable key on the ADM
to
disable the ADM.
3.
Turn main power switch (MP) to OFF position.
4.
Close A (Red) and B (Blue) fluid supply valves (FV).
5.
Perform Pressure Relief Procedure on page 66.
6.
Shut down feed pumps as required. See feed pump
manual.
ti9883a1
FV