Component Identification
22
313997A
Main Power Switch
Located on top of the power distribution box, see
page
. The main power switch turns power
ON
and OFF
. The main power switch
does not turn pumps or heat zones on.
Circuit Breakers
Most circuit breakers are located inside the power distri-
bution box. The main block of circuit breakers in the
power distribution box is shown below, with detailed
information in the following table. For more information
about items in the power distribution box, see power dis-
tribution box manual 3A0239 for more information.
Additional circuit breakers for protection of the second-
ary side of the heated hose transformer are located
inside the frame. See the parts list for the installed pri-
mary/hose heat option. See Ref. 5 of the product config-
urator code for your machine to determine which
primary/hose heat option is installed. See Product Con-
figurator on page 5.
Ref.
Size
Component
230V/
1 phase,
400V/
3 phase
230V/
3 phase
CB1
63A
30A
Motor Control Module
CB2
40A
40A
Primary Heater A
CB3
15A
15A
Tank Heat A
CB4
40A
40A
Hose Heat A
CB5
5A
5A
Miscellaneous
CB6
5A
5A
Miscellaneous
CB7
40A
40A
Hose Heat B
CB8
15A
15A
Tank Heat B
CB9
40A
40A
Primary Heater B
CB1
CB5
CB4
CB2
CB3
CB9
CB7
CB6
CB8
24C681_313998_1e
CB579
CB718
B (Blue)
Left Side from Rear View
A (Red)
Right Side from Rear View
24C332_313998_3f
24C332_313998_6f