Models
4
313997A
Models
See Product Configurator on page 5 for detailed prod-
uct configuration information.
*
Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and
mix chamber sizes may be less.
** Values are dependent on installed pump size. Values shown are for largest available pump size.
†
210 ft (64 m) maximum heated hose length, including whip hose.
◆
Flow rate is independent of frequency 50/60 Hz.
★
approved.
‡ The maximum fluid working pressure for the base machine without hoses is 3000 psi (20.7 MPa, 207 bar). If
hoses rated at less than 3000 psi are installed, the system maximum fluid working pressure becomes the rating of
the hoses. If 2000 psi hoses were purchased and installed by Graco, the working pressure for the machine is
already setup for the lower 2000 psi (13.8 MPa, 138 bar) working pressure by Graco. If the machine was pur-
chased without hoses and aftermarket hoses rated less than 3000 psi are to be installed, see instruction manual
313998 for the procedure to setup the machine for lower rated hoses. The change to lower working pressure is
made by changing a rotary switch setting in the Motor Control Module. The minimum pressure rating for hoses is
2000 psi. Do not install hoses with a pressure rating lower than 2000 psi.
System
Full Load
Peak Amps
Per Phase*
Voltage
(phase)
System
Watts†
Primary
Heater Watts
(per heater)
Max Flow
Rate
◆
**
lb/min (kg/min)
Approximate
Output per
Cycle (A+B)**
gal. (liter)
Hydraulic
Pressure
Ratio**
Maximum
Fluid Working
Pressure ‡
psi (MPa, bar)
HFR,
Non-Heated
55 A
230V (1)
12,650
--
50 (22.7)
0.084
(0.318)
1.9:1
3000
(20.7, 207)
29 A
230V (3)
11,340
55 A
★
400V (3)
12,650
HFR,
Heated
116 A
230V (1)
26,680
6,000
50 (22.7)
0.084
(0.318)
1.9:1
3000
(20.7, 207)
73 A
230V (3)
28,600
75 A
★
400V (3)
28,600