Integration
72
333587D
Communications Gateway Module (CGM)
Overview
The Communications Gateway Module (CGM) provides
a control link between the E-Flo iQ system and a
selected fieldbus. This provides the means for report
monitoring and control by external automation systems.
NOTE:
The following system network configuration files
are available at
help.graco.com.
• EDS file: DeviceNet or EtherNet/IP fieldbus
networks
• GSD file: PROFIBUS fieldbus networks
• GSDML: PROFINET fieldbus networks
NOTE:
See the Supply System Communications
Gateway Module Installation Kit manual for CGM
installation. See
Related Manuals
on page
E-Flo iQ and PLC Connection Setup
Verify that the PLC parameters are set up correctly, see
the Gateway Map table.
NOTE:
If the PLC connection parameters are not setup
correctly, the connection between the E-Flo iQ and PLC
will not be made.
Available Internal Data
Unless stated otherwise, bytes are stored in each
instance in little endian order (byte order within
instance: most significant to least significant).
NOTE:
Automation Outputs can be monitored by the
corresponding Automation Inputs to verify that the
E-Flo iQ received the data.
See the
Automation Outputs
on page
and the
Automation Inputs
E-Flo iQ Ambient Map
Gateway Map Token: 18E218
Map Name on ADM: E-Flo iQ Adv
Comm. Format
Data-SINT
Input Assembly Instance:
100
Input Instance Size:
70
Output Assembly Instance:
150
Output Instance Size:
24
E-Flo iQ Heated Map
Gateway Map Token: 18E224
Map Name on ADM: E-Flo iQ Adv Heat
Comm. Format
Data-SINT
Input Assembly Instance:
100
Input Instance Size:
94
Output Assembly Instance:
150
Output Instance Size:
40