
Setup
26
333587D
Style Screen 3 - Integration
Use the ADM Directional Keypad (CH) to navigate to
Style screen 3.
NOTE:
You can only make changes to this screen in
Remote mode. In Local mode, the screen appears as
shown below.
1. In Remote mode, press the
soft key to enter
editing mode.
2. Set Style Enable and Go Signal fields to either
Discrete or Fieldbus depending on your
requirements. It is recommended that you select
Discrete for the Go Signal to avoid start and stop
delays.
3. Set Dispense Complete to Discrete, Fieldbus, or
Timer. If you select Timer, enter the number of
seconds for the timer from 0-999.
4. Press the
soft key to save your changes and
exit editing mode.
Pump Settings
Press the
soft key at iQ Menu screen 1 to access
the Pump setup screens. This function allows you to
configure the operating settings for the pump and drum
depending on the mode of operation.
Pump Screen 1 - Pump Settings
The following description is the same for both Ram and
Tandem selections. For Tandem, Pump 1 and Pump 2
are shown in the Menu Bar. Use the ADM Directional
Keypad to select each pump for configuration. The
Tandem screen is shown below.
NOTE:
in Tandem systems, it is recommended that
both pumps should be configured with identical pimp
settings.
Follow these steps to configure the operating settings
for each pump in a Tandem system or a single pump in
a Ram system.
1. Press the
soft key to enter editing mode.
2. Configure the Over Pressure setting by entering a
pressure limit.