Integration
76
333587D
91
Pump Data Exchange Element Value Feedback uint32
See pump data
exchange for min
and max values
0-30 66-69
A
Transition To Heated Map 18E224
92
Heat Heartbeat To PLC
Boolean
0
1
0
70
H
93
System Heat Enabled
Boolean
0
1
1
H
94
Heat PLC Lockout/Control Active
Boolean
0
1
2
H
95
Heat is On
Boolean
0
1
3
H
96
Heat is Warming Up
Boolean
0
1
4
H
97
Heat is At Temperature
Boolean
0
1
5
H
98
Heat is in Temperature Soak Mode
Boolean
0
1
6
H
99
Heat is in Setback Mode
Boolean
0
1
7
H
100
Heat is Off
Boolean
0
1
0
71
H
101
No Heat Module Alarms are Present
Boolean
0
1
1
H
102
No Heat Module Deviations are Present
Boolean
0
1
2
H
103
No Heat Module Advisories are Present
Boolean
0
1
3
H
104
No Heat Zone(s) Alarms are Present
Boolean
0
1
4
H
105
No Heat Zone(s) Deviations are Present
Boolean
0
1
5
H
106
No Heat Zone(s) Advisories are Present
Boolean
0
1
6
H
107
Heat Idle Timeout Happened
Boolean
0
1
7
H
108
Reserved Bit 1
Boolean
-
-
0
72
H
109
Reserved Bit 2
Boolean
-
-
1
H
110
Reserved Bit 3
Boolean
-
-
2
H
111
Reserved Bit 4
Boolean
-
-
3
H
112
Reserved Bit 5
Boolean
-
-
4
H
113
Reserved Bit 6
Boolean
-
-
5
H
114
Reserved Bit 7
Boolean
-
-
6
H
115
Reserved Bit 8
Boolean
-
-
7
H
116
Reserved Bit 9
Boolean
-
-
0
73
H
117
Reserved Bit 10
Boolean
-
-
1
H
118
Reserved Bit 11
Boolean
-
-
2
H
119
Reserved Bit 12
Boolean
-
-
3
H
120
Reserved Bit 13
Boolean
-
-
4
H
121
Reserved Bit 14
Boolean
-
-
5
H
122
Reserved Bit 15
Boolean
-
-
6
H
123
Reserved Bit 16
Boolean
-
-
7
H
124
Module Heat Soak Time Remaining
(xx seconds)
uint16
0
7200
0-14 74-75
H
E-Flo iQ Maps 18E218 and 18E224
Automation INPUTS (signal from E-Flo iQ to PLC)
Instanc
e ID
Description
Data
Type
Min
Value
Max
Value
Bit
Byte
Heat