Maintenance
50
333587D
Maintenance
Press the
soft key at iQ Menu screen 2 to access
the Maintenance screens. The Maintenance screens
are the same for Tandem and Ram except Pump 2 will
show in the Menu Bar. Use the ADM’s Directional
Keypad (CH) to navigate to Pump 2.
Pump Maintenance Screen 1
The Maintenance and Pump Position screen allows you
to set maintenance parameters and view and change
the pump position.
1. Press the
soft key to enter editing mode.
2. For the Driver, Pump, Platen, Platen Valve, and
Dispense Valve, you can enter a Limit for the
number of cycles that can be run before a message
is issued that maintenance is needed. Use the
navigation arrows to move between selections and
enter the number using the numeric keypad (BJ).
3. To reset the Cycles counter, use the navigation
arrows to move to each one you want to reset and
press the
soft key.
NOTE
: Reset the counter after maintenance is
completed.
4. Press the
soft key to exit editing mode.
Press the
soft key to enter manual pump
movement mode. The arrow keys on the right side of
the screen move the pump’s driver rod up and down.
The driver rod on the picture of the pump will move to
represent the action.
NOTE:
The arrow keys are only available if the driver is
calibrated and not already in use.
Press and release the
soft key to move the driver
rod to the top.
Press and hold the
soft key to move the driver rod
up. The driver rod will move up as long as the soft key
is held or until it reaches the top.
Press and hold the
soft key to move the driver rod
down. The driver rod will move down as long as the soft
key is held or until it reaches the bottom.
Press and release the
soft key to move the driver
rod to the bottom.
NOTE:
A medium force and relatively slow speed is
used.
Press the
soft key to exit the manual pump
movement mode.