Integration
74
333587D
25
E-Flo iQ Mode Active
Boolean
0
1
0
3
A
26
Changeover Occurred during Dispense
Boolean
0
1
1
A
27
Reserved Bit 1
Boolean
-
-
2
A
28
Reserved Bit 2
Boolean
-
-
3
A
29
Reserved Bit 3
Boolean
-
-
4
A
30
Reserved Bit 4
Boolean
-
-
5
A
31
Reserved Bit 5
Boolean
-
-
6
A
32
Reserved Bit 6
Boolean
-
-
7
A
33
Actual Pump Flowrate (xxxx cc/min)
uint16
0
6000
0-14
4-5
A
34
Outlet Pressure (xxx.x bar)
uint16
0
413.6
0-14
6-7
A
35
Valve Pressure (xxx.x bar)
uint16
0
413.6
0-14
8-9
A
36
Active Style Loaded (xx)
uint16
0
16-99
0-14 10-11
A
37
Active Style Precharge (xxx.x bar)
uint16
0
413.6
0-14 12-13
A
38
Active Style Flowrate (xxxx cc/min)
uint16
0
6000
0-14 14-15
A
39
Reserved Word 1
uint16
-
-
0-14 16-17
A
40
Actual Amount Dispensed
(xxx.xx cc)
uint32
0
21,474,
836.00
0-30 18-21
A
41
Reserved Word 2
uint32
-
-
0-30 22-25
A
42
Actual Style Fieldbus Pre-charge Request
(xxx.x bars)
uint16
0
413.6
0-14 26-27
A
43
Actual Style Fieldbus Flowrate Request
(xxxx cc/min)
uint16
0
6000
0-14 28-29
A
44
Reserved Word 3
uint16
-
-
0-14 30-31
A
45
Pump Position (x.xxxx inches)
uint16
0.0000
4.0000
0-14 32-33
A
46
Actual Style Valve On Delay (xxxx ms)
uint16
0
5000
0-14 34-35
A
47
Actual Style Valve Off Delay (xxxx ms)
uint16
0
5000
0-14 36-37
A
48
Actual Style Motor On Delay (xxxx ms)
uint16
0
5000
0-14 38-39
A
49
Actual Style Motor Off Delay (xxxx ms)
uint16
0
5000
0-14 40-41
A
50
Actual Fieldbus Valve On Delay (xxxx ms)
uint16
0
5000
0-14 42-43
A
51
Actual Fieldbus Valve Off Delay (xxxx ms)
uint16
0
5000
0-14 44-45
A
52
Actual Fieldbus Motor On Delay (xxxx ms)
uint16
0
5000
0-14 46-47
A
53
Actual Fieldbus Motor Off Delay (xxxx ms)
uint16
0
5000
0-14 48-49
A
54
Pump Data Exchange Element Feedback
uint16
0
32767
0-14 50-51
A
55
Pump Data Exchange Element Value Feedback uint32
See pump data
exchange for min
and max values
0-30 52-55
A
E-Flo iQ Maps 18E218 and 18E224
Automation INPUTS (signal from E-Flo iQ to PLC)
Instanc
e ID
Description
Data
Type
Min
Value
Max
Value
Bit
Byte
Heat