Troubleshooting
333587D
57
A8__
AMZ
Alarm
No Current H_Z_
Power is not
getting to
heating
element
Power not getting
to heating element
Check fuse on the AMZ that the error
element is connected to.
Check that electrical connector on the
heated hose is plugged into the AMZ.
Check continuity of pins C and D on
electrical connector at AMZ end of heated
element. See heated element manual for
impedance measurements. Replace hose if
readings are too high.
CAC_
ADM
Alarm
Communication
Error P_
Communicatio
n lost between
ADM and pump
No 24 VDC power
supply to ADM
Reconnect or replace CAN cable
connecting driver and ADM. If CAN
connection good, check 24V power supply
wiring in driver. Make sure AC power to
pump is turned off before checking power
supply. Yellow LED on driver connector
board should be flashing.
Cross threaded
CAN cable
CAN cables carry 24 V DC power and
communication between modules. A cross
threaded CAN cable connector may cause
problems with communication and/or power
to modules. Carefully check for cross
threaded CAN connections on the ADM and
driver. Yellow LED on driver connector
board should be flashing.
CBD_
Driver
Alarm
Communication
Error P_
Communicatio
n lost between
pump and ADM
No AC power to
driver
Verify pump is turned on by confirming
disconnect switch is in the ON position.
Yellow LED on driver connector board
should be flashing.
AC disconnect
switch broken
Disconnect pump from AC power. Check
wiring to switch. If wiring is good, replace
the AC disconnect switch.
Ribbon cable
disconnected
Disconnect pump from AC power. Verify
that the ribbon cable inside driver casing is
connected.
Faulty driver
control board
Replace driver control board.
CBGX
Gateway
Alarm
Fieldbus Reset
The fieldbus
has performed
a reset
Changing the
fieldbus setup
properties
No action necessary.
CBT_
AMZ
Alarm
Communication
Error H_
Communicatio
n lost between
AMZ MZLP4
and ADM
No AC power to the
AMZ MZLP4
Verify AMZ MZLP4 is turned on by
confirming disconnect switch of the heat
box is in the ON position.
AC disconnect
switch broken
Disconnect AMZ MZLP4 from AC power.
Check wiring to switch. If wiring is good,
replace the AC disconnect switch of the
heat box.
Faulty AMZ MZLP4
control board
Replace AMZ MZLP4 control board.
Error Location Type
Error Name
Error
Description Cause
Solution