Pump
16
3A5082G
Illuminated Remote Run Button
Available on DMS enabled models only.
Parts:
25C981 - 12VDC
25C982 - 24 VDC
Installation
Install the remote run button in an easily accessible
location inside the truck cab.
1.
Drill a hole in the panel. (See the
illustration on the right for cutout
dimension. The maximum panel
thickness is 0.472 in./12.0 mm).
2.
Remove the lock nut (51a) from
the push button (51). Install the
o-ring (54) (F
. 15).
3.
Insert the push button (51) through the hole drilled
through the panel in Step 1. Hand tighten the lock
nut (1a) to secure the push button in place (F
. 15).
4.
Clean the surface around the outer edge of the push
button (1). Position label (53) around the button and
adhere label (F
5.
Clean the an area close to the push button for
mounting the label (55) inside cab. Adhere label to
mounting surface.
6.
Connect the wiring connector (52) to the push
button and the pump. See Pin and Related Wire
Color Table (below) and Wiring information shown in
F
Pin and Related Wire Color (F
Ref Part No.
Description
Qty
51
Push button
1
52
Connector
4
53
Button Label
1
54
O-ring
1
55
129336 Cab Information Label
1
F
IG
. 14
F
IG
. 15
51
52
53
54
55
0.748” [19.0 mm]
51
54
51a
F
IG
. 16
Pin
Pin Name
Color
1
Not Used
Not Used
2
-VDC
Black
3
+VDC
Red
4
LED+
White
5
Manual Run Switch
Orange
6
Not Used
Not Used
7
LED-
Green
53
51
55
Содержание 24Z660