Sample System Event Log
Example Event Log
: The pump cycle of a typical
lubrication system is shown below.
Common System Events are listed below.
System Event Log
DMS ID Number: 00613
Software Part No.: 17J936
Software Version: 0703
09/29/2016 14:1400
Date
Time
Description
9/29/2016
14:13:02
Pump Run Off
9/29/2016
14:13:02
Program Variable Change
9/29/2016
14:12:39
Pump Run On
9/29/2016
14:12:34
Local Manual Run Initiated
Pump Run On
The pump entered an on cycle and is
operating and dispensing material.
Pump Run Off
The pump entered an off cycle and is
not dispensing.
Pump Run
Canceled
A pump on cycle was canceled by
pressing the cancel button on the front
panel and holding it for 3 seconds.
Program Variable
Change
The setup mode was entered.
Local Manual Run
Initiated
The manual run button was pressed,
initiating a pump on cycle.
Remote Manual
Run Initiated
The remote manual run button was
pressed initiating a pump on cycle.
Successful Pin
Code Entry
The pin code was successfully entered
and the user has entered setup mode.
Cold Delay
The pump entered a cold delay
Firmware Update
Completed
The firmware was updated successfully.