![Graco 24Z660 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/graco/24z660/24z660_instructions-manual_2251638038.webp)
Pump
38
3A5082G
Motor
Current
Warning
The measured motor
current is above the
recommended operating
maximum value. Continued
use at excessive motor
currents could reduce life
or cause permanent
damage.
Pump tries running cycle
90 times before shutting
down. See Pump
Over-current Protection,
page 15.
Examine system to make
sure it is operating
correctly. A blocked line
could create excessive
motor current
Examine pump to ensure
that it is rotating properly.
If necessary, contact
Graco Customer Service.
Motor
Current Fault
The measured motor
current was above the
recommended operating
maximum value 90 times.
Continued use at excessive
motor currents could
reduce life or cause
permanent damage.
Examine system to make
sure it is operating
correctly. A blocked line
could create excessive
motor current
Examine pump to ensure
that it is rotating properly.
If necessary, contact
Graco Customer Service.