Pump
3A5082G
35
•
When the ON Time count reaches zero, the pump
shuts off again and the system again runs OFF
Time cycle and the OFF Time LED is now again
illuminated (F
. 29).
This sequence repeats itself until the device is
reprogrammed or an alarm occurs.
•
If power to the pump is lost during a lubrication
cycle, when power is restored the pump will resume
the cycle with the same amount of time remaining in
the cycle as when the power was lost.
Cold Delay
In DMS models, when the pump powers on when the
temperature is below 14°F (-10°C), there is a 15 minute
cold delay before the pump resumes running the
program.
-
When power to the unit cycles OFF then ON.
-
Temperature is below14°F (-10°C).
-
Unit immediately begins the Cold Delay count
down and then the pump resumes.
-
The LED next to the clock in the OFF field is
illuminated (F
. 31).
-
The Cold Delay LED lights (F
-
The display shows time remaining until the
pump resumes. The example shown in F
shows 8 minutes and 14 seconds left until the
pump resumes.
Manual Run Cycle
To run an extra (non-programmed)
lubrication cycle, push the Manual Start
button.
F
IG
. 30
F
IG
. 31
Содержание 24Z660
Страница 7: ...Typical System Installation 3A5082G 7 FIG 4 ...
Страница 11: ...Pump 3A5082G 11 Pump Dimensions FIG 7 ...
Страница 13: ...Pump 3A5082G 13 Mounting Bracket and Pump Dimensions FIG 9 ...
Страница 67: ...Notes 3A5082G 67 Notes ...