Safety Features and Precautions
This instrument fulfills the requirements of the applicable Euro-
pean and national EC guidelines. We confirm this with the CE
marking. The relevant declaration of conformity can be obtained
from GMC-I Messtechnik GmbH.
The
PROFITEST 204+
, 204 HP and 204 HV test instruments have
been manufactured and tested in accordance with the following
safety regulations:
IEC 61010-1 / DIN EN 61010-1 / VDE 0411-1,
DIN VDE 0413, part 1, and EN 60204 / DIN VDE 0113
If used for their intended purpose, the safety of the user, the
instrument and the device under test is assured.
Read the operating instructions thoroughly and carefully before using
your instrument, and follow all instructions included therein.
Make sure that the operating instructions are readily available to all oper-
ators.
Observe the following safety precautions:
• The instrument may only be connected to electrical supply
systems with 230 V/240 V which conform to the valid safety
regulations (e.g. IEC 60364, VDE 0100) and are protected with
a fuse or circuit breaker with a maximum rating of 16 A.
• Be prepared for the occurrence of unexpected voltages at
devices under test (for example, capacitors may be
dangerously charged).
• Make certain that connector cables, measurement cables and
test cables are in flawless condition, e.g. no damage to
insulation, no interruptions in cables or plugs, no kinks etc
.
• Impulse withstand voltages of up to 2.5 kV may occur in
overvoltage category II systems with 230/400 V.
The PROFITEST 204+ basic instrument and the PROFITEST 204HP and HV
high-voltage modules may not be operated:
• If visible damage is apparent
• If connector, measuring or test cables are damaged
• If they no longer function correctly
• If the signal lamps are defective
• If the functions test is not passed (see chapter 4.5.1, page 35)
In such cases, the instrument must be removed from service and
secured against unintentional use. Send the instrument to the
Repair and Replacement Parts Service Department (see chapter 13).
Opening of Equipment / Repair
The equipment may be opened only by authorized service per-
sonnel to ensure the safe and correct operation of the equipment
and to keep the warranty valid. Even original spare parts may be
installed only by authorized service personnel.
In case the equipment was opened by unauthorized personnel,
no warranty regarding personal safety, measurement accuracy,
conformity with applicable safety measures or any consequential
damage is granted by the manufacturer.
Data Backup
The measurement, report and input data are stored and secured
in the test instrument RAM as long as the associated battery sup-
plies the required voltage. Please note that the data will be lost
during a software update. We therefore advise you to regularly
transmit your stored data to a PC in order to prevent potential loss
of data in the test instrument. We assume no responsibility for any
data loss. For data processing and management we recommend
the following PC software programs:
• ETC
•
PS3
(documentation, management, report generation and
monitoring of deadlines)
•
PC.doc-WORD™/EXCEL™
(report and list generation)
•
PC.doc-ACCESS™
(test data management)
•
ELEKTROmanager
for
PROFITEST 204+
Содержание PROFITEST 204
Страница 75: ...GMC I Messtechnik GmbH 75 ...