58
GMC-I Messtechnik GmbH
PROFITEST 204HP-2.5kV
* Recommended
** The highest value applies
PROFITEST 204HV
* Recommended
PROFITEST 204HV-5.4kV
* Recommended
Reference Conditions
Line Voltage
230 V
1%
Line Frequency
50 Hz
0.1%
Waveshape
sine (deviation between effective
and rectified values < 1%)
Ambient Temperature
+ 23
C
2 K
Relative Humidity
40% ... 60%
Load Impedance
ohmic
Nominal Ranges of Use
Line Voltage
207 V ... 253 V
Line Frequency
45 Hz ... 65 Hz
Line Voltage Waveshape
sine
Temperature Range
0
C ... + 40
C
Ambient Conditions
Storage Temperature
– 20
C ... + 60
C
Operating Temperature
– 5
C ... + 40
C
Accuracy
0
C ... + 40
C
Max. Relative Humidity
75%, no condensation allowed
Elevation
to 2000 m
Power Supply
Line Voltage
207 V ... 253 V
Line Frequency
45 Hz ... 65 Hz
Power Consumption
204:
approx.
180 VA
without
accessories
204HP:
max.
700 VA
204HV:
max.
100 VA
Max. Leakage Current
0.5 mA
basic device and 204HP or HV
Power Consumption
max. 6 A
basic device and 204HP or HV
RS 232 Interface
Type
RS 232C, serial, per DIN 19241
Format
9600, 8, N, 1
Connector
9-pin sub-miniature socket
Parameter
Lower Limit
Standard Value Upper Limit
Special Setting
Options
Test Duration
1 s
1 s
120 s
Continuous
Test Voltage
250 V
1 kV
or 2 x U
N
**
2.5 kV
Breaking Current I
MAX
10 mA
—
200 mA
Pulse control mode
Rise Time
100 ms
1 s *
99.9 s
Parameter
Lower Limit
Standard Value Upper Limit
Special Setting
Options
Test Duration
1 s
—
120 s
Continuous
Test Voltage
650 V
—
5 kV
Breaking Current I
MAX
1 mA
—
10 mA
Pulse control mode
Rise Time
100 ms
1 s *
99.9 s
Parameter
Lower Limit
Standard Value Upper Limit
Special Setting
Options
Test Duration
1 s
—
120 s
Continuous
Test Voltage
250 V
—
5.35 kV
Breaking Current I
MAX
0.5 mA
—
10 mA
Pulse control mode
Rise Time
100 ms
1 s *
99.9 s
Содержание PROFITEST 204