p
rodUCt
s
peCifiCations
p
rodUCt
s
peCifiCations
34 www.goodmanmfg.com
SS-CPC36-72
w
iring
d
iagram
— CpC036-72*4B/7B (460v/575
v
, B
elt
d
rive
)
Wiring is subject t
o chang
e. Alw
ay
s
re
fer
to the wiring diagr
am or the
unit
for the mos
t up-t
o-da
te
wiring.
⚠
W
arning
High
Volt
ag
e:
Disc
onn
ect
all
po
w
er
be
for
e
ser
vicing
or
in
st
alling
this
unit.
Multiple
po
w
er
sour
ces
ma
y
be pr
esen
t. F
ailur
e
to do
so ma
y
cause pr
operty
damag
e,
per
sonal
injur
y,
or dea
th.
⚡
H
1
PU
2
GR
3
BR
Y1
T
BL
3 6
/
4
RD
YL
6
0
WH
PU
LVJB
PLF 2
5
GND
OR
PU
YL
YL
F
T
CONTROL
BR
T1
O
1
4
BR
BR
BK
9
RD
R
RCCF
3
C
W2
T
PLF 1
BL
7
5
PU
T3
G
T2
R
WH
A
GR
CM
W1
RD
8
E
YL
M
2
BL
S
BOX
++
YL
COMP
C
Y/Y2
6
LPS
HPS
BL/PK
YL/PK
TB1
PU
OR
O
RD
GR
BK
NOTE #2
GR
C
RD
SEE
NOTE #2
BK
BL
T1
T2
M2
3
YL
BK
EBTDR
BL
YL/PK
M1
K1
L1
BK
PU
RD
BR
1
K1
24V
L2
BR
C
GR
TR
NO
NC
BL
RD
BK
T3
208
L3
2
0
8
-
2
4
0
-
4
6
0
-
5
7
5
RD
BL
COM
/
RD
RD
BK
BK
RD
PK
TB1
SMOKE/FIRE DETECTOR
REPLACES JUMPER
S1
2
240
460
575
S2
RD
BL
G
XFMR-R
XFMR-C
BK
SPEED
C
UP
R
BL
RD
BL
OR
GR
T3
BK
BC
T1
RD OR
C
EM
T2
L1
L2
L3
208-240-460-575/3/60 0140L00427 REV. B
SEE NOTE #3
C
RCCF
EBTDR
C
L2
R
4
T3
T1
5
Y
Y2
COMP
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND
TYPE INSULATION AS ORIGINAL (AT LEAST 105°C)
USE COPPER CONDUCTOR ONLY.
2. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE
3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR
COMPARTMENT, REMOVE MALE PLUG, ATTACH
FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
4. FOR 208 VOLT TRANSFORMER OPERATION MOVE
BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2
ON TRANSFORMER.
T2
O
G
P
L
F
1
THERMOSTAT
3
6
F
208-240-460-575/3/60 0140L00427 REV. B
Y1
R
COMPONENT LEGEND
G
SUPPLY VOLTAGE
CM
W2
EM
L1
W1
C
T1
6
BC
C
CM
CMR
COMP
DC
DFT
ECON
EBTD
EMR
R
EM
FC
GND
HPS
HVDR
LPS
LVDR
LVJB
PB
PLF
RVC
RCCF
TB1
TR
3
C
1
C
C
24V
PLF2
C
T3
L3
BLOWER CONTACTOR
CONTACTOR
CONDENSER MOTOR
CONDENSER MOTOR RELAY
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
ECONOMIZER
ELECTRONIC BLOWER TIME DELAY
EVAPORATOR MOTOR RELAY
RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
EQUPIMENT GROUND
HIGH PRESSURE SWITCH
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
POWER DISTRUBTION BLOCK
FEMALE PLUG / CONNECTOR
REVERSING VAVLE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
TERMINAL BLOCK (24V SIGNAL)
TRANSFORMER
TR
4
OF OVER CURRENT PROTECTION
5
BC
SEE UNIT RATING PLATE FOR TYPE AND SIZE
208-240V
208-240/3/60
T2
P
L
F
1
2
1
BC
EBTDR
R
EBTDR
HPS
LPS
BC
TB1
TB1
BC
++
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE
OPTIONAL
HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
BL
RD
OR
Y1
Y/Y2
YL
W
Y/Y2
BL
G
R
OR
W
NO ECONOMIZER
G
OR
YL
RD
Y/Y2
Y1
PK
WH
W
R
RD
WH
GR
C
O
R
YL
O
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTAT
FIELD WIRING
BL
C
O
2 STAGE COOLING
TB1
G
R
W
Y
C
O
TB1
TB1
Y
W
O
R
G
C
W
Y2
G
R
C
O
Y1
STAT
STAT
STAT
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLE
PK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW