SS-CPC36-72
www.goodmanmfg.com
31
Wiring is subject t
o chang
e. Alw
ay
s
re
fer
to the wiring diagr
am or the
unit
for the mos
t up-t
o-da
te
wiring.
⚠
W
arning
High
Volt
ag
e:
Disc
onn
ect
all
po
w
er
be
for
e
ser
vicing
or
in
st
alling
this
unit.
Multiple
po
w
er
sour
ces
ma
y
be pr
esen
t. F
ailur
e
to do
so ma
y
cause pr
operty
damag
e,
per
sonal
injur
y,
or dea
th.
⚡
w
iring
d
iagram
—
CpC036/48*3d (t
hree
p
hase
, d
ireCt
d
rive
)
H
1
RCCF
T
PU
CONTROL
BR
C
2
T1
T3
T1
GR
BK
O
1
YL
4
BR
3
BR
T1
BK
9
RD
COMP
R
BR
FC
T2
3
C
W2
T
Y1
PLF 1
3
T
YL/PK
PU
F
BL
3 6
7
5
PU
T3
G
T2
COMPONENT LEGEND
BL
L1
SUPPLY VOLTAGE
CM
BK
R
EM
/
L1
4
T1
RD
YL
6
0
BC
BIR
C
CM
COMP
EM
GND
HPS
LPS
PLF
FC
TB1
TR
WH
C
A
GR
CM
W1
YL
8
E
RD
M
C
C
2
PU
S
L2
BLOWER CAPACITOR
BLOWER INTERLOCK RELAY
CONTACTOR
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUPIMENT GROUND
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
FEMALE PLUG / CONNECTOR
FAN CAPACITOR
TERMINAL BLOCK (24V SIGNAL)
TRANSFORMER
TR
BOX
OF OVER CURRENT PROTECTION
PLF 2
BL
BK
5
++
YL
COMP
SEE UNIT RATING PLATE FOR TYPE AND SIZE
208-240V
O
208-240/3/60
T2
2
0
8
-
2
4
0
BK
Y/Y2
/
GND
6
1
PB
TB1
BL
BL
208-240/3/60 0140L00505 REV A
SEE NOTE 3
24V
RD
RD
T2
L2
YL
T3
L3
C
T3
L3
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND
TYPE INSULATION AS ORIGINAL (AT LEAST
105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE
M1 OR M2 WIRE TO COM TERMINAL ON EBTDR
AND PLACE WIRE REVMOVED FROM COM ON
EMPTY M1 OR M2 TERMINAL.
3. FOR 208 VOLT TRANSFORMER OPERATION
MOVE BLACK WIRES FROM TERMINAL
3 TO TERMINAL 2 ON TRANSFORMER.
4. USE COPPER CONDUCTORS ONLY ++ USE N.E.C.
CLASS 2 WIRE
5. ECONOMIZER PLUG LOCATED IN THE RETURN
AIR COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO ECONOMIZER
ACCESSORY.
6. DIAGRAM SHOWS FACTORY SPEED TAP SETTINGS.
WH
GR
TB1
F
LPS
YL/PK
YL
BL
RD
OR
Y1
Y/Y2
YL
W
Y/Y2
BL
G
R
OR
W
NO ECONOMIZER
G
OR
YL
RD
Y/Y2
Y1
PK
WH
W
R
RD
WH
GR
C
O
R
YL
O
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTAT
FIELD WIRING
BL
C
O
2 STAGE COOLING
TB1
G
R
W
Y2
C
O
TB1
TB1
Y
W
O
R
G
C
W
Y2
G
R
C
O
Y1
STAT
STAT
STAT
C
BL/PK
HPS
BL
PU
BR
C
RD
2
3
K1
RD
RD
BK
BC
PU
24V
COM
TR
UP
BL
M2
BK
240
GR
NC
SPEED
EBTDR
PU
R
XFMR-R
XFMR-C
BL
G
K1
M1
EM
NO
1
SEE
NOTE #2
RD
BK
BL
C
3 SPEED
BR
BL
BK
208
SMOKE/FIRE DETECTOR
REPLACES JUMPER
TB1
S2
S1
PK
BK
RD
BR
BL
BIR
BK
BR
EBTDR
BR
8
9
7
R
O
HPS
C
LPS
SEE NOTE 5
Y/
Y2
TB1
5
6
PLF
G
C
Y1
W1
4
THERMOSTAT
W2
2
PLF2
1
3
6 5 4
R
R
C
G
EBTDR
XFMR
PU
ALTERNATE
MOTOR
6-WIRES
SEE TABLE 1
BC
3 SPEED
BL
EM
RD
BK
BR
RD
PU
TABLE 1
ALTERNATE MOTOR WIRING
TABLE 2
SPEED TAPS
COLOR
RD
BK
BL
PU
TERMINATION
COM (EBTDR)
M1 (EBTDR)
M2 (EBTDR)
PIN 1 (24V XFMR)
RD
BL
BK
LOW
MED
HIGH
BL
OR
BK
BK
PU
OR
BK
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE
OPTIONAL
HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
GR GREEN
WIRE CODE
BL BLUE
PU PURPLE
PK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
1
3
2