SS-CPC36-72
www.goodmanmfg.com
35
w
iring
d
iagram
— CpC060*3d
(s
ingle
p
hase
, d
ireCt
d
rive
)
Wiring is subject t
o chang
e. Alw
ay
s
re
fer
to the wiring diagr
am or the
unit
for the mos
t up-t
o-da
te
wiring.
⚠
W
arning
High
Volt
ag
e:
Disc
onn
ect
all
po
w
er
be
for
e
ser
vicing
or
in
st
alling
this
unit.
Multiple
po
w
er
sour
ces
ma
y
be pr
esen
t. F
ailur
e
to do
so ma
y
cause pr
operty
damag
e,
per
sonal
injur
y,
or dea
th.
⚡
T
CONTROL
BR
T1
BK
BK
PLF 1
PU
T3
T2
CM
RD
YL
BOX
++
COMP
BK
TB1
5
1 2
N
RD
BL
4
3
EM
G
L
C
GR
BL
LPS
YL
YL
PU
BR
WH
OR
YL/PK
HPS
PU
WH
BK
H
C
RD
RD
1
PU
2
GR
BK
O
1
YL
4
BR
3
BR
T1
9
RD
R
BR
3
RCCF
3
C
W2
BL
BK
T
Y1
T
YL/PK
PU
BL
3 6
7
5
G
BL
L1
BK
R
/
4
RD
YL
6
0
WH
1
A
GR
24V
W1
8
E
M
C
2
PU
BL
S
TR
LVJB
PLF 2
BL
BK
5
YL
C
208
2
0
8
-
2
4
0
BL
Y/Y2
/
GND
6
BK
TB1
SMOKE/FIRE DETECTOR
REPLACES JUMPER
PK
RD
BL
RD
2
240
YL
YL
RD
T2
L2
RD
T3
L3
WH
GR
F
WH
YL
WH
YL
GR
TB1
1
5
OR
OR
S2
S1
O
YL
BR
OR
RD
BK
208-240/3/60 0140L0 0428 REV B
RCCF
C
4
T3
T1
5
COMP
T2
3
6
F
COMPONENT LEGEND
SUPPLY VOLTAGE
CM
EM
L1
T1
C
CM
COMP
EM
GND
HPS
LPS
LVJB
PLF
RCCF
TB1
TR
3
C
1
PLF2
C
L2
CONTACTOR
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUPIMENT GROUND
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
CONDENSER FAN
TERMINAL BLOCK (24V SIGNAL)
TRANSFORMER
TR
OF OVER CURRENT PROTECTION
SEE UNIT RATING PLATE FOR TYPE AND SIZE
208-240V
208-240/1/60
T2
2
1
N
G
208-240/3/60 0140L0 0428 REV B
SEE NOTE 3
SEE NOTE 2
W2
24V
THERMOSTAT
4
W1
Y1
C
G
PLF
6
5
TB1
C
T3
L3
Y/
Y2
SEE NOTE 5
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND
TYPE INSULATION AS ORIGINAL (AT LEAST
105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE
WHITE AND YELLOW LEADS FROM "3" AND "4"
TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED,
THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION
MOVE BLACK WIRES FROM TERMINAL 3 TO
TERMINAL 2 ON TRANSFORMER.
4. USE COPPER CONDUCTORS ONLY ++ USE N.E.C.
CLASS 2 WIRE
5. ECONOMIZER PLUG LOCATED IN THE RETURN
AIR COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO ECONOMIZER
ACCESSORY.
TB1
L
5
1
2
N
4
3 EM G
L
C
TB1
LPS
C
HPS
O
R
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE
OPTIONAL
HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
BL
RD
OR
Y1
Y/Y2
YL
W
Y/Y2
BL
G
R
OR
W
NO ECONOMIZER
G
OR
YL
RD
Y/Y2
Y1
PK
WH
W
R
RD
WH
GR
C
O
R
YL
O
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTAT
FIELD WIRING
BL
C
O
2 STAGE COOLING
TB1
G
R
W
Y2
C
O
TB1
TB1
Y
W
O
R
G
C
W
Y2
G
R
C
O
Y1
STAT
STAT
STAT
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLE
PK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW