p
rodUCt
s
peCifiCations
p
rodUCt
s
peCifiCations
SS-CPC36-72
www.goodmanmfg.com
5
p
rodUCt
s
peCifiCations
— CpC060
CPC060
XXX1DXXXB
CPC060
XXX3DXXXB
CPC060
XXX3BXXXB
CPC060
XXX4BXXXB
CPC060
XXX7BXXXB
Cooling Capacity
Total BTU/h
59,500
59,500
59,500
59,500
59,500
Sensible BTU/h
43,200
43,200
43,200
43,200
43,200
SEER / EER
13 / 11.3
13 / 11.3
13 / 11.0
13 / 11.0
13 / 11.0
Decibels
78
78
78
78
78
ARI Reference #s
4385056
4385057
4385057
4385058
4397606
Evaporator Motor / Coil
Motor Type
Direct
Direct
Belt
Belt
Belt
Indoor Nominal CFM
2,000
2,000
2,000
2,000
2,000
Expansion Device
Piston
Piston
Piston
Piston
Piston
Piston Size (Cooling)
0.086
0.086
0.086
0.086
0.082
Filter Size (")
(4) 14 x 20 x 2
(4) 14 x 20 x 2
(4) 14 x 20 x 2
(4) 14 x 20 x 2
(4) 14 x 20 x 2
Drain Size (NPT)
¾"
¾"
¾"
¾"
¾"
R-410A Refrigerant Charge (oz.)
162
162
162
162
162
Face Area (ft²)
7.8
7.8
7.8
7.8
7.8
Rows Deep/ Fins per Inch
4 / 16
4 / 16
4 / 16
4 / 16
4 / 16
Tube Diameter - Material
5/16 - Copper
5/16 - Copper
5/16 - Copper
5/16 - Copper
5/16 - Copper
Evaporator Fan
Standard Direct Drive (D x W) HP
(11" X 10") 1
(11" X 10") 1
---
---
---
Standard Belt Drive (D x W) HP
---
---
(11" X 10") 1
(11" X 10") 1
(11" X 10") 1½
High-Static Belt Drive (D x W) HP
---
---
(11" X 10") 1½
(11" X 10") 1½
(11" X 10") 1½
Belt Drive Evap Fan Data
# of Wheels (D x W)
---
---
1 (11" x 10")
1 (11" x 10")
1 (11" x 10")
Motor Sheave
---
---
VL44 x ⅝
VL44 x ⅝
VL44 x ⅝
Blower Sheave / Belt
---
---
AK61x1 / AX53
AK61x1 / AX53
AK61x1 / AX53
Condenser Fan / Coil
Horsepower / RPM
¼ / 1,090
¼ / 1,090
¼ / 1,090
¼ / 1,090
¼ / 1,075
Fan Diameter/ # Fan Blades
22 / 4
22 / 4
22 / 4
22 / 4
22 / 4
Outdoor Nominal CFM
3,800
3,800
3,800
3,800
3,800
Face Area (ft²)
17.0
17.0
17.0
17.0
17.0
Rows Deep/ Fins per Inch
2 / 18
2 / 18
2 / 18
2 / 18
2 / 18
Tube Diameter - Material
5/16 - Copper
5/16 - Copper
5/16 - Copper
5/16 - Copper
5/16 - Copper
Compressor
Quantity / Type
1 / Scroll
1 / Scroll
1 / Scroll
1 / Scroll
1 / Scroll
Stage
Single
Single
Single
Single
Single
Compressor RLA / LRA
26.4 / 134
16 / 110
16 / 110
7.8 / 52
5.7 / 38.9
Electrical Data
Voltage-Phase-Frequency
208/230-1-60
208/230-3-60
208/230-3-60
460-3-60
575-3-60
Indoor Blower HP / FLA
1.0 / 7.6
1.0 / 7.6
1.0 / 3.8
1.0 / 1.9
1.5 / 2.3
Indoor Blower LRA
24
----
24
12
12
Outdoor Fan HP / FLA
¼ / 1.40
¼ / 1.40
¼ / 1.40
¼ / 0.80
¼ / 0.60
Min. Circuit Ampacity¹
42
29
25
12
10
Max. Overcurrent Protection²
60 amps
45 amps
40 amps
20 amps
15 amps
Power Supply Conduit Hole
1.125"
1.125"
1.125"
1.125"
1.125"
Low-Voltage Conduit Hole
½"
½"
½"
½"
½"
Operating Weight (lbs)
580
580
580
580
580
Ship Weight (lbs)
605
605
605
605
605
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.