Section 5 - Procedures
TS200
TS200 Menu Table with EZcal (continued)
ADJUSTMENTS
UP MIN(*)
Determines the slowest lifting speed (when the joystick is at 0% demand)
UP MAX(*)
Determines the fastest lifting speed (when the joystick is at 100% demand)
DOWN MIN(*)
Determines the slowest lowering speed (when the joystick is at 0% demand)
DOWN
MAX(*)
Determines the fastest lowering speed (when the joystick is at 100% demand)
ACCEL
Determines the rate of increase of lift/lower speed when higher speeds are demanded
ti:
DECEL
Determines the rate of decrease of lift/lower speed when lower speeds are demanded
::J
Determines the height above which lifting is prevented. Set to prevent lift above the set height. Ensure to set
MAX LIFT
MAX LIFT so that the lift cylinder does not go to end of stroke and over pressurizes (it
will
be interpreted as an
overloaded platform!)
TIME
Determines the time delay when armguard triggers during lowering, before lowering is allowed to continue.
ARMGUARD
Determines the height at which "soft armguard" occurs when lowering. Set to zero to trigger "soft armguard"
@HEIGHT
at the ELEVATION@ height, or nonzero to trigger at the set height IMPORTANT: If armguard function is not
needed, choose 101% to disable.
w
UP(*)
Determines the (fixed) lifting speed in ground mode
Cl
0
DOWN(*)
Determines the (fixed) lowering speed in ground mode
Cl
ACCEL
Determines the rate of increase of lift/lower speeds in ground mode
0
DECEL
Determines the rate of decrease of lift/lower speeds in ground mode
DRIVE
Determines when to sound the alarm - set to "NO" to not sound while driving, to "FWD" or "REV" to sound
while driving in that direction, or to "BOTH" to sound for driving in either direction.
(/)
Determines when to sound the alarm - set to "NO" to not sound while lifting/lowering, to "UP" or "DOWN" to
cc
LIFT
:'.5
sound while lifting or lowering, or to "BOTH" to sound for lifting and lowering.
�
TILT
Determines when to sound the alarm - set to "NO" to not sound depending on tilt, to "ELEVATED" to sound if
tilted and elevated, or to "ALWAYS" to sound when tilted irrespective of platform height.
CHANGE
Select this menu to check correct customer / vehicle model configuration, and/or select new vehicle model
DEFAULTS
defaults
(/)
TILT SETUPS
Select this menu to calibrate tilt (on level ground) and configure tilt shutdown
w
HEIGHT SET-
(/)
Select the menu to calibrate height measurement
UPS
LOAD SETUPS
Select this menu to calibrate overload and to configure certain overload related options
62
1330ED
&
1530ED micro
GMG
Содержание 1330-ED
Страница 4: ...Notes 4 1330ED 1530ED micro GMG...
Страница 24: ......
Страница 25: ...Section 2 Maintenance Tables and Diagrams 25 1330ED 1530ED micro GMG...
Страница 31: ...Section 3 System Component Identification and Schematics 31 1330ED 1530ED micro GMG...
Страница 38: ...Notes 1330ED 1530ED micro GMG...
Страница 69: ...Notes 69 1330ED 1530ED micro GMG...