TS200
Section 5 - Procedures
Display Messages and Codes (Continued)
Display
EZcal Display Message
Description
Code
The platform and ground EMS inputs indicate the mode in
2-1
SHUTDOWN - CHECK EMS SWITCHES!
which the TS200 must operate. If neither input is active, or
if both are active together, the TS200 does not know how to
function Check EMS switch wiring to P15-1 and P12-1.
FUNCTIONS LOCKED - TOO HIGH
The platform is raised too high to allow some functions.
FUNCTIONS LOCKED - OVERLOADED
The platform is loaded too high to allow operation - the plat-
form load must be reduced.
Platform overload features are active, and the platform load
FUNCTIONS LOCKED - UNDERLOADED
is too low to be valid - this could be caused by erroneous
calibration, a sensor fault, or a change in the vehicle mechan-
ics/hydraulics.
FUNCTIONS LOCKED - EXTERNAL
An external shutdown is preventing functions - check DIAG-
SHUTDOWN
NOSTICS/SYSTEM/MODE/ INTERLOCK to see which external
interlock is active.
FUNCTIONS LOCKED - TILTED
The platform joystick was selected for too long without trigger
switch.
During descent, the TS200 can stop movement for a con-
FUNCTIONS LOCKED - ARMGUARD (CE
figurable time (see ADJUSTMENTS/ LIFT/ ARMGUARD), to
ONLY)
allow a safety check that no-one is close to the vehicle. The
operator must release and then re-select DOWN to continue
lowering (after the delay timeout).
2-2
RELEASE GROUND SWITCHES!
Base control function switches were closed at power-on (or a
wiring error is causing an input to be active always).
RELEASE JOYSTICK SWITCHES!
The platform joystick was not in neutral at power-on (or a wir-
ing error is causing an input to be active always).
The platform trigger switch was closed at power-on (or a wir-
RELEASE TRIGGER!
ing error is causing the input to be active always)
The platform trigger switch was closed for too long with no
function selected.
There is a problem with the platform drive/lift select switch -
SELECT DRIVE/LIFT MODE!
neither mode is selected Check wiring from drive/lift select
switch.
FAULT: MOTOR CONNECTIONS
The TS200 has detected multiple power wiring faults on mo-
SHORTED
tors A and/or B.
CHECK DRIVE/LIFT SELECT SWITCH!
There is a problem with the platform drive/lift select switch -
both modes are selected together.
CHECK GROUND INPUT SWITCHES!
There is a problem with the ground function select switches -
more than one is active at the same time.
CHECK JOYSTICK!
There is a problem with the platform joystick.
53
1330ED
&
1530ED micro
GMG
Содержание 1330-ED
Страница 4: ...Notes 4 1330ED 1530ED micro GMG...
Страница 24: ......
Страница 25: ...Section 2 Maintenance Tables and Diagrams 25 1330ED 1530ED micro GMG...
Страница 31: ...Section 3 System Component Identification and Schematics 31 1330ED 1530ED micro GMG...
Страница 38: ...Notes 1330ED 1530ED micro GMG...
Страница 69: ...Notes 69 1330ED 1530ED micro GMG...