Section 5 - Procedures
TS200
TS200 Menu Table with EZcal (continued)
SYSTEM
::,
PLATFORM
z
w
:::;
GROUND
Cl)
INPUTS
Cl)
z
ANALOGS
OUTPUTS
LOG
MODE
MODE/
INTERLOCK
SUPPLY
SUPPLY/
LowBatt
SUPPLY/
DeadBatt
SUPPLY/ BCI
MtrV
:::;
Mtrl
w
TEMPERATURE
TILT
TILTED
HEIGHT
LOAD
OVERLOADED
LAST MOVED
ELEVATED
58
DIAGNOSTICS
Select this menu to see general TS200 system information
Select this menu to see platform input status
Select this menu to see ground input status (during calibration, separate measurements are collected during
lifting and lowering)
Select this menu to see other input status
Select this menu to see analog input status
Select this menu to see TS200 output status
Select this menu to see logged information
Displays current operating mode or interlock
When current operating mode shows INTERLOCKED, press ENTER to see the reason for the interlock; press
ESC to return to the current operating mode
Displays battery supply voltage
Indicates when battery is "low" (see SETUPS / BATTERY)
Indicates when battery is "low" (see SETUPS / BATTERY)
Displays the estimated battery charge (see SETUPS/ BATTERY)
NOTE: BCI is also displayed on the platform control box Display Module
Displays motor voltage of both motors (will be equal, unless steering)
Displays motor current of both motors
Displays motor voltage of both motors (will be equal, unless steering)
Displays motor current of both motors
Displays tilt values (X
0
,
Y
0
)
Displays whether system is in tilted mode (measured tilt ex-ceeds tilt trip points)
Displays platform height, calculated from height sensor(s) and data stored during calibration. Press ENTER
when viewing the HEIGHT (which is the average of the two sensors), to see the individual measurements of the
two sensors, named HEIGHT1 and HEIGHT2 (press e and g to see both); press ESC to return to the average
HEIGHT
Displays platform load, esti-mated from lift cylinder pres-sure measurement, platform height, and heighVpres-
sure curves stored during calibration
Displays whether system is in overload mode (platform load exceeds load trip point, aVabove overload height)
Displays whether the most re-cent platform movement was UP or DOWN; this is important if the lift cylinder
pressure is affected by the direction of movement
Displays whether system is in elevated mode
1330ED
&
1530ED micro
GMG
Содержание 1330-ED
Страница 4: ...Notes 4 1330ED 1530ED micro GMG...
Страница 24: ......
Страница 25: ...Section 2 Maintenance Tables and Diagrams 25 1330ED 1530ED micro GMG...
Страница 31: ...Section 3 System Component Identification and Schematics 31 1330ED 1530ED micro GMG...
Страница 38: ...Notes 1330ED 1530ED micro GMG...
Страница 69: ...Notes 69 1330ED 1530ED micro GMG...