86
Ventless Hood
GBF Ventless Electric Fryer
GBF-35D & 50D-VH
EAC
Pin at back of Hood must align
with hole in rear of Cell.
Airflow Arrow on
front of Cell
must point
upward.
1
1
2
ON
Illuminates to indicate that the EAC Cell is
installed and powered. This is the only
indicator
ON
when the EAC is functioning
normally.
WASH/CHECK
These two indicators turn
ON
, to signal a
condition requiring attention. Two (2)
minutes after these lights turn
ON
, a
beeping alarm sounds and the heating
elements shutdown. On a Computer
Control unit the message
“ERROR ALARM
- CLEAN THE EAC”
is displayed on the
Upper Display
③.
This is NOT
APPLICABLE on Manual Control units
.
There are various causes for this
condition. Typically, the reason is
excessively dirty collection fins in the Cell;
it must be cleaned as described in
Section
7.01.8
. Other possible causes include;
damaged Cell, poor connection (dirty
contacts), missing ionizer wires, faulty
wiring, or electronic malfunction
.
Three L.E.D. indicator lights on the Control Panel show the operational status of the Electronic Air Cleaner (EAC).
IMPORTANT! DO NOT use the WASH/CHECK indicators a
signal to perform routine cleaning. To maintain peak
performance, the EAC cell must be cleaned daily as described
in
Section 7.01.8
.
If no L.E.D. indicators light up when the Power Switch is
turned ON, the EAC system may have an internal
malfunction. A qualified service technician will be required.
2
If all (3) LED’s turn ON at power-up, the EAC cell is not
installed, it is mis-aligned, there is a poor connection, or
other problems exist. After (2) minutes, the EAC system will
go into an alarm condition and disable the unit.
3
1. Ensure the airflow indicator arrow on front of Cell
points upward.
2. Align Cell in the guides and slide into the Hood.
Front of Cell must be flush with Hood front. If not,
it is not installed properly.
3. Replace Access Cover and latch.
NOT ON MANUAL CONTROL UNITS
7.01.6
E.A.C. Filter Cell Installation
7.01.7
E.A.C. Filter Operation
Содержание GBF Series
Страница 2: ......
Страница 4: ......
Страница 12: ...x Safety GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 16: ...4 Introduction GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 32: ...20 Overview GBF Ventless Electric Fryer GBF 35D 50D VH 5 6 2 4 1 3 7 3 03 Lower Cabinet ...
Страница 36: ...24 Overview GBF Ventless Electric Fryer GBF 35D 50D VH 2 1 3 7 4 5 6 8 3 05 Ventless Hood ...
Страница 48: ...36 Pre Operation GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 110: ...98 Troubleshooting GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 118: ...106 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH 9 05 Lower Cabinet Rear 8 3 1 10 4 5 6 7 2 5 9 ...
Страница 122: ...110 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH Not shown 9 07 Ventless Hood Front 8 3 1 4 5 6 7 2 ...
Страница 126: ...114 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH A 9 09 Filter Pan 8 3 1 4 5 6 7 2 10 9 ...
Страница 128: ...116 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 129: ......