54
Fryer Operation
GBF Ventless Electric Fryer
GBF-35D & 50D-VH
5.01.11
Controller Errors & Alarms
Certain conditions, which can cause unsafe operation or damage to the unit, such as
open valves, low oil level, high temp, etc. will activate error
codes and sound an alarm tone. Error Codes are shown on
the
Lower 7-Segment Display
; error information is shown on
the
Upper OLED Display
. Typically, the heating elements are
disabled until the error condition is corrected. Pressing the
ALARM
key silences the alarm tone, but does not clear the
error. Error Codes are shown on the following Table; details are presented in the
following section.
OLED
7-Segment
ERROR CODE DESCRIPTION (OLED Display)
PROBLEM
OPEN
DRAIN IS OPEN
Drain valve is open, or not completely closed. Basket will be
raised if it is down. Close drain to clear error.
----
CHECK OIL LEVEL, ENSURE VAT IS
FULL, IF FULL THEN PRESS
[START]
This is a secondary error displayed after closing drain clears the
OPEN error; allows confirmation of oil level.
ER07
MAX ELEMENT TEMP – PRESS
[START] (Post Warning)
Error is displayed after MAX element temperature (ER19) has
occurred and the element has cooled below MAX temperature, .
ER13
OIL PROBE Error
Problem with the Variable Oil Temp Probe.
Service technician
required.
ER15
ELEMENT PROBE Error
Problem with the Element Temp Probe, typically attached
directly to heating element.
Service technician required.
ER19
MAX ELEMENT TEMP Error
The maximum heating element temperature has been exceeded.
This is a safety device;
NEVER bypass this Probe.
ER21
BAFFLE FILTER MISSING
Ventless Fryers (VH) Only ...
Baffle Filter is missing, or
improperly installed.
ER22
CHARCOAL FILTER MISSING
Ventless Fryers (VH) Only ...
Charcoal Filter is missing, or
improperly installed.
ER23
FILTER CLOGGED
Ventless Fryers (VH) Only ...
pressure switch is not engaging.
Indicates airflow restriction; Charcoal Filter is clogged, or other
obstructions. Replace Filter, remove obstruction.
ER24
EAC CELL DIRTY
Ventless Fryers (VH) Only ...
EAC Filter Cell is dirty and needs to
be cleaned. This error can have also have other causes.
ER25
GUARD BAND EXCEEDED
Actual oil temperature deviates from setpoint by the Guard
Band amount. Allow oil to cool, or heat, to within range.
Factory default is 900
°
F ...
Error should not occur
.
ER37
EEPROM Error
An error occurred while saving settings to the EEPROM.
Contact
Giles Tech Service (800.554.4537).
ER38
Internal ADC Error
The ADC (Analog-to-Digital Converter) chip that reads output
from thermocouples is not working. MCB1 board must be
replaced.
Contact Giles Tech Service (800.554.4537).
Содержание GBF Series
Страница 2: ......
Страница 4: ......
Страница 12: ...x Safety GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 16: ...4 Introduction GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 32: ...20 Overview GBF Ventless Electric Fryer GBF 35D 50D VH 5 6 2 4 1 3 7 3 03 Lower Cabinet ...
Страница 36: ...24 Overview GBF Ventless Electric Fryer GBF 35D 50D VH 2 1 3 7 4 5 6 8 3 05 Ventless Hood ...
Страница 48: ...36 Pre Operation GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 110: ...98 Troubleshooting GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 118: ...106 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH 9 05 Lower Cabinet Rear 8 3 1 10 4 5 6 7 2 5 9 ...
Страница 122: ...110 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH Not shown 9 07 Ventless Hood Front 8 3 1 4 5 6 7 2 ...
Страница 126: ...114 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH A 9 09 Filter Pan 8 3 1 4 5 6 7 2 10 9 ...
Страница 128: ...116 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 129: ......