89
Ventless Hood
Error Message
[Error Code]
What will happen
Filter
Affected
Cause
Solution
See Section
ERROR ALARM - BAFFLE
FILTER MISSING
[Er21]
●
Continuous tone alarm.
●
Power to heating elements is
shutdown.
●
Blower also shuts down (only
for ILS on Manual)
Baffle
The Filter is not
installed, or is
mis-aligned, not
actuating the
filter switch.
Install filter.
Check filter
alignment.
7.01.2 &
7.01.3
ERROR ALARM -
CHARCOAL FILTER
MISSING
[Er22]
●
Continuous tone alarm.
●
Power to heating elements is
shutdown.
●
Blower also shuts down (only
for ILS on Manual)
Charcoal
The Filter is not
installed, or is
mis-aligned, not
actuating the
filter switch.
Install filter.
Check filter
alignment.
7.01.10
ERROR ALARM -
CLOGGED FILTER
[Er23]
●
Continuous tone alarm.
●
Power to heating elements is
shutdown.
●
Blower also shuts down (only
for ILS on Manual)
Charcoal or
Baffle
Airflow
restriction is
present.
Charcoal or
Baffle Filter
clogged.
Other possible
restrictions.
Replace Charcoal
Filter, about every
30 days.
Clean Baffle Filter.
Check for other
airflow
restrictions.
7.01.4 &
7.01.11
ERROR ALARM - CLEAN
THE EAC
[Er24]
●
Beeping
tone alarm.
●
Power to heating elements is
shutdown after 2 mins.
●
Blower also shuts down (only
for ILS on Manual)
E.A.C.
Filter Cell is dirty.
Cell not installed.
Contacts dirty.
Other fault
conditions.
Clean Filter Cell
Install Cell
properly.
7.01.7 & 7.01.8
The following table explains the various Filter Alarms which may occur. When an alarm condition occurs, an audible
alarm tone sounds. It will be either a continuous tone or an intermittent (beeping) tone, depending on the type of
the alarm. See
Section 5.1.10.1, Resolving Errors and Alarms
for more information.
7-Segment
Lower Display
OLED
Upper Display
Computer
Manual
NOTE: Error messages shown in the Table below only apply Computer Controller units.
Filter
Missing Light
EAC Status
Lights
EAC Status
Lights
GBF Ventless Electric Fryer
GBF-35D & 50D-VH
7.01.11 Filter Alarm Chart
Содержание GBF Series
Страница 2: ......
Страница 4: ......
Страница 12: ...x Safety GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 16: ...4 Introduction GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 32: ...20 Overview GBF Ventless Electric Fryer GBF 35D 50D VH 5 6 2 4 1 3 7 3 03 Lower Cabinet ...
Страница 36: ...24 Overview GBF Ventless Electric Fryer GBF 35D 50D VH 2 1 3 7 4 5 6 8 3 05 Ventless Hood ...
Страница 48: ...36 Pre Operation GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 110: ...98 Troubleshooting GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 118: ...106 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH 9 05 Lower Cabinet Rear 8 3 1 10 4 5 6 7 2 5 9 ...
Страница 122: ...110 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH Not shown 9 07 Ventless Hood Front 8 3 1 4 5 6 7 2 ...
Страница 126: ...114 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH A 9 09 Filter Pan 8 3 1 4 5 6 7 2 10 9 ...
Страница 128: ...116 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH ...
Страница 129: ......