BA230
36
UK
13
20
14
21
30
22
23
24
25
26
28
27
29
JP5
JP4
15
18
16
19
17
COM
START
EL1
PED
STOP
FCAM1
FCCM1
FCAM2
FCCM2
RESERVE
PH2
SAFETY
EDGE
EL2
+ ACC
GND
+ SAF
WARNING
LIGHT
Negative electrical lock
START (N.O.) input
Po12 Vdc motor 1 electrical lock
PEDESTRIAN input (N.O.)
Not used
STOP input (N.C.).
If not used, jumper with terminal n° 32
Limit switch input opens motor 1 (N.C.).
If not used, disable during the programming phase.
Limit switch input closes motor 1 (N.C.).
If not used, disable during the programming phase.
Limit switch input opens motor 2 (N.C.).
If not used, disable during the programming phase.
Limit switch input closes motor 2 (N.C.).
If not used, disable during the programming phase.
Multitasking input
PHOTOCELL 2 input (N.C.).
If not used, disable during the programming phase or jumper with terminal n° 32
Operation
:
Input enabled during both opening and closing.
If intercepted, it stops the motion immediately and holds it stopped until the photocell
is freed. Upon release, motion always starts in opening.
If intercepted when the gate is closed, following a Start command it does not allow
the opening of the gate: this will be signalled with 5 fast flashes, then the warning
light turns on to indicate that the door is not in stand-by. Upon release, the gate will
start opening without further commands.
If intercepted during pause, it reloads the pause time.
SAFETY DEVICES input (see menu C9)
If not used, disable during the programming phase or jumper with terminal n° 32
Operation
:
Input enabled during both opening and closing.
It stops and inverts the motion for 2 s. The gate will remain locked until the next
Start pulse, which will make it start in the obstacle-freeing direction.
If the input is enabled when the door is in stand-by, after a Start or a Pedestrian
command the door will not move and 3 long flashes (2 sec.) will signal the fault.
If the input is enabled when the door is in pause, the door does not close
automatically (if automatic closing is enabled) and 3 long flashes (2 sec.) will
signal the fault.
Po12 Vdc motor 2 electrical lock
External accessories (photocells, radio…) +24Vdc power supply
Negative external accessories power supply
External safety d24Vdc power supply.
CAUTION
: output present only during the operating cycle
Warning light 24 Vdc 3W max
Operation
:
Slow flashing during opening,
fixed light during pause, f
ast flashing during closing
External watch
:
SEE PROGRAMMING
E9