BA230
46
UK
C13
C21
OLEODYNAMIC
BLOCK MAINTENANCE
SELF - LEARNING
2
AUTO
Enables the hydraulic block maintenance function
ONLY FOR HYDRAULIC OPERATORS
Operation
:
If in the last 5 hours the gate has not performed a manoeuvre,
a 2 s pulse in closing is given.
The enabling of the STOP key in any moment disables the function.
The function is automatically disabled with SLIDING - DEAD MAN
configuration
Enables times programming in self-learning
Operation
:
See “Times self-learning procedure”
A C
F
H E
F 1
ESC
ESC
-
-
OK
OK
+
+
When the display shows the main menus (letters ACFHE or just some
of them depending on which password was used to access
programming) let the letter F blink by moving to the right or to the left
with the b or –
Once the letter F blinks confirm with the OK button
By means of + or – buttons you can select the submenus (F2, F3, F4)
The digits on the lcd are fixed to show that is no possible any modification.
The button ESC lets you to go to the upper level (menus A, C, F, H E).
With OK button you enter the selected menu and the value set is shown.
MENU F: FORCE AND SPEED ADJUSTEMENT
0 0 0 5
0 0
0
5
ESC
ESC
-
-
OK
OK
+
+
The digits on the lcd are still fixed to shown that is not possible any
modification.
The b and – are irrelevant.
The ESC button return to the upper level
With OK button you enter the selected menu and the digits begin
blinking.
A digit of the lcd blinks (depending on the menu the blinking digit could
be different).
With + and – buttons you can modify the value of the blinking digit.
The ESC button moves the blinking digit to the left until the first digit
you can modify.
With OK you confirm and go to the next step.
Example Programming