WARNINGS FOR THE USER
In the event of an operating fault or failure, cut the power upstream of the control unit and call the Technical
Service.
Periodically check the functioning of the safety devices. Any repairs must be carried out by specialised personnel
using original and certified materials.
The appliance is not to be used by children or people with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction.
Do not touch the card for adjustments and/or maintenance.
WARNING: IMPORTANT SAFETY INSTRUCTIONS.
It is very important to follow the present instructions for your own safety.
Please keep this manual.
ELECTRICAL CONNECTIONS: FASTON
Cable colour
BLACK
RED
BLUE
Terminal
CF1
CF3
CF2
CF4
CF5
CF6
CF7
CF8
CF9
CF10
Description
Primary connection of 230Vac transformer
Secondary connection of 14Vac transformer
Secondary connection of 22Vac transformer
Motor 2 capacitor connection
Motor 1 capacitor connection
Description
JP1
JP2
Terminal
Power supply 23Vac
1
Position
Signal
L
Power supply 230Vac
2
N
Ground wire connection
3
GND
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
4
7
8
9
10
11
12
5
6
GND
OPEN
COM
CLOSE
OPEN
COM
CLOSE
LAMP
LAMP
Ground wire connection
Flashing light output 230 Vac 40W max
Flashing light output 230 Vac 40W max
Motor 1 connection 1 (opening)
Common motor 1
Motor 1 connection 1 (closing)
Motor 2 connection (opening)
Common motor 2
Motor 2 connection (closing)
Operation
:
Fast flashing during opening,
off during pause,
slow flashing during closing