![GI.BI.DI AS05581 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/gi-bi-di/as05581/as05581_installation-instructions-manual_2220603055.webp)
UK
BA230
55
LIMIT SWITCHES OPERATION
RESET
If you enable the deceleration function, the limit switches mark the beginning of the deceleration. The gate will
keep on his decelerated motion for the time set up in H3 and H6 menus.
If you use the double reading of limit switches, the first reading starts the deceleration and the second one stops
it, but it doesn't stop the motion if T3 and/or the end stroke in opening/closing are activated.
Make sure that the times set are higher than the time necessary to reach the limit switch.
If deceleration is not enabled, the limit switches lock the motion.
The additional time T3 and the final opening/closing stroke, if enabled, work even when there are limit switches.
Press and hold simultaneously ESC and OK keys for 3 s until the writing “PASS” appears on the display.
Then press and hold simultaneously the + and – keys for 3 s.
The default settings will be loaded into memory and will lose all previous settings except the number of
performed cycles and powered days.
FLASHING LIGHT SIGNALS SUMMARY
Device
Signal
Effect
Photo 2 intercepted in stand-by after a
start command
Edge intercepted in stand-by after a start command
Edge intercepted in pause after a start command
or at closing
Photo 1 test failed at opening
Photo 1 test failed at closing
TRIAC test failed at opening
TRIAC test failed at closing
Edge N.C. test failed at opening
Edge N.C. test failed at closing
Edge 8K2 test failed at opening
Edge 8K2 test failed at closing
Expired maintenance
5 fast flashings
3 slow flashings
3 slow flashes
4 fast flashings
4 fast flashings
4 slow flashings
4 slow flashings
3 slow flashings
3 slow flashings
2 slow flashings
2 slow flashings
1 minute slow flashing with
closed door
When released, it opens
Blocked closed door
Blocked open door
Blocked closed door
Blocked open door
Blocked closed door
Blocked open door
Blocked closed door
Blocked open door
Blocked closed door
Blocked open door
None