Instruction Manual
ION Director®
EN
2021-01-23
11
TIP
•
The sensor is sensitive to interference due to the low signal level. To
obtain the best measurement results, it is therefore necessary to
ensure sufficient distance between the sensor and its cable and
sources of interference (e.g. ballasts, power lines, pumps,
entertainment electronics, etc.).
3.2.2
PAB-Ports
PAB devices are connected to the black RJ45 Western sockets. These are on the one hand the
control unit (
ProfiLux 3/4/4e
or
GHL Doser Standalone
), on the other hand possibly existing
further slave devices. Please also refer to the instructions in the operating manual of the
corresponding control unit.
3.2.3
AUX Port
This mini DIN socket can be used to connect devices with AUX plugs.
3.2.4
Return Vent
Return to the aquarium and ventilation.
3.2.5
Power Supply
24 VDC
hollow socket
. The
ION Director®
does not have its own power supply. The device needs
to be connected to the power supply of the
GHL Doser 2.1
via the power supply splitter-cable.
To install, first connect each Y-ends of the splitter cable to the DC-connector of the
ION
Director®
(24 VDC, polarity: , outside -) and
GHL Doser 2.1
. Connect then the other end
of the splitter to the main power supply of the Doser.
Please note that the
ION Director®
and the
GHL Doser
are operated with
24 V
,
ProfiLux
on the
other hand runs with
12 V
. It is therefore not possible to tap the supply voltage for the ION
Director® from the ProfiLux.
Never connect 12 V consumers to 24 V power supplies (or vice versa), this will inevitably lead
to malfunction or destruction!
Use only the supplied original cables and power supplies for supplying power to the
ION
Director®
device.