NRG 1x-60 - Installation & Operating Manual -
819681-00
Starting, operation and testing
The operating panel:
1
Display of actual value/fault code/limit value, green, 4 digits
2
LED 1, alarm/fault, red
3
LED 2, function OK, green/flashing during self-test
4
Rotary knob/push-button for operation and settings
OK
!
+
-
1
2
3
4
Notes on the priority of the various indications
Fault indications and alarms are displayed based on their priority. Indications with higher prio-
rity are shown continuously before those with low priority. if several indications need attention,
the display does not alternate between them.
Priority 1 = fault indications as per fault code table,
see page 48
ff.
Priority 2 = low-level alarm
Priority of fault code display
Higher priority fault codes overwrite lower ones on the display!
Fig. 22