16
NRG 1x-60 - Installation & Operating Manual -
819681-00
Technical data
Model and mechanical connection
■
■
NRG 16-60, NRG 17-60, NRG 19-60
Thread G¾ A, EN ISO 228-1, see Fig. 8
■
■
NRG 111-60
Thread G1 A, EN ISO 228-1, see Fig. 9
Nominal pressure rating, admissible service pressure and temperature
■
■
NRG 16-60
PN 40
32 bar (g) at 238 °C
■
■
NRG 17-60
PN 63
60 bar (g) at 275 °C
■
■
NRG 19-60
PN 160
100 bar (g) at 311 °C
■
■
NRG 111-60
PN 320
183 bar (g) at 357 °C
Materials
■
■
Terminal box
3.2581 G AlSi12, powder-coated
■
■
Sheath
1.4301 X5 CrNi 18-10
■
■
Electrode extension
1.4401 X5 CrNiMo 17-12-2
■
■
Electrode insulation of
NRG 16-60, NRG 17-60, NRG 19-60
Gylon
®
■
■
Electrode insulation NRG 111-60
Special ceramics
■
■
Screw-in body:
■
◆
NRG 16-60, NRG 17-60, NRG 19-60 1.4571, X6CrNiMoTi17-12-2
■
◆
NRG 111-60
1.4529, X1NiCrMoCuN25-20-7
pH value
■
■
NRG 111-60
Maximum admissible = 10
Electrode lengths supplied
■
■
500 mm, 1000 mm, 1500 mm, 2000 mm, 2500 mm, 3000 mm
■
■
The electrode extension can be shortened
Conductivity range at 25 °C
■
■
0.5 μS/cm to 10,000 μS/cm
Sensitivity
■
■
0.1 μS/cm at an immersion depth of 5 mm, with measuring surface extension
Supply voltage
■
■
24 V DC +/-20 %
Power consumption
■
■
max. 7 VA