LX-80-15 10 Hz User Manual
4
LX-80-15 10 Hz Oceanographic Radar Sensor
Picture 2. Serial RS232 DB-9 Cable
3.1. Serial RS-232 Interface
Serial RS-232 interface is implemented as standard PC full-duplex serial interface with voltage
levels adequate for direct connection to PC computers or other embedded devices used for serial
RS-232 communication.
When the RS-232 interface is connected to a standard DB-9 PC connector, TxD line (green wire)
is connected to pin 2 and RxD (yellow wire) is connected to pin 3. In order for the serial interface
to operate properly, an additional connection of signal GND (grey wire) is needed on pin 5 of the
DB-9 connector. Optionally, Geolux can supply a cable with DB-9 connector connected to the
cable. This requirement must be specified when placing an order.
Several communication protocols are available. Additional custom protocols can be implemented
on request. Detailed description of communication protocols is given in chapter 8 of this user
manual.
3.2. Serial RS-485 Interface
Serial RS-485 interface is implemented as standard industrial half-duplex communication
interface. The communication interface is internally short-circuited, and overvoltage protected.
Depending on the receiving device, the interface can be used with only two wires (D+ dark red
wire & D- orange wire) while in some cases the ground connection (signal GND grey wire) is also
required. For more details please consult receiver specification.
The most common communication protocol used with RS-485 interface is Modbus-RTU, but other
protocols are also available on request. Detailed description of communication protocols is given in
chapter 8 of this user manual.