LX-80-15 10 Hz User Manual
23
LX-80-15 10 Hz Oceanographic Radar Sensor
7
Data Interface
Geolux LX-80-15 10 Hz radar sensor offers multiple data interfaces, in order to make the integration of
the device with existing SCADA/telemetry systems easy.
7.1. Serial RS-232 Interface
Serial RS-232 interface is used for direct connection of a single level meter unit with the computer. The
serial interface is used both for retrieving live level measurements and for configuration of the level
meter device. Geolux provides a PC application for instrument configuration and level monitoring free of
charge.
Default communication parameters are:
Bitrate: 115200 bps
Data bits:
8
Stop bits:
1
Parity:
None
A NMEA-like communication protocol is used to deliver level measurements over the RS-232 interface.
Detailed description of the protocol is given in chapter 8 of this user manual.
7.2. Serial RS-485 Interface
Serial RS-485 interface is used for connecting multiple level meters to a single data logger. RS-485
interface uses a different protocol then the protocol used over RS-232 interface, in order to allow
multiple level meters connected on a single RS-485 bus. The main difference from the protocol used over
RS-232 interface is that the level measurements are not reported automatically but are instead reported
only after being requested by the master device (data logger unit). LX-80 supports Modbus protocol
over RS-485 bus. Detailed description of the protocol is given in chapter 8 of this user manual.
Default communication parameters are:
Bitrate:
9600 bps
Data bits:
8
Stop bits:
1
Parity:
Even
Device ID:
1