LX-80-15 10 Hz User Manual
44
LX-80-15 10 Hz Oceanographic Radar Sensor
Name
Command
Response
Details
Save background
signal level
d!
a+d<CR><LF>
Stores the radar echo curve
signature from zero distance up
to defined distance d. The stored
echo curve is used as a reference
signal background level, and only
reflections stronger than the saved
level will be used when searching
for the water level. To clear this
setting, send this command with a
parameter d set to 0 (zero).
+d – distance in currently used
units
Wake up from sleep
mode
aXGLWU!
a+0<CR><LF>
When the instrument is configured
to operate in SDI-12 mode,
it goes to sleep until SDI-12
measure command (xM!) is issued.
Connection to the instrument
through RS-232 and RS-485
interfaces is not possible while
the instrument is in the sleep
mode. To facilitate connecting
to the instrument from the PC
application, after issuing this
command, the instrument will
wake up and remain in active
state for 60 seconds. During that
time, a connection over serial
cable can be established using
Geolux Instrument Configurator
PC application. If the connection is
established within this 60-second
period, the instrument will remain
in the active state as long as the
PC application is connected to the
instrument.
Clear the stored
radar calibration,
perform self-
calibration,
and store new
calibration
parameters.
aXGCLR!
a+1<CR><LF>
Forces the instrument to clear
the stored radar calibration, and
to perform the self-calibration
again. In majority of cases the
factory calibration will be valid
through the whole lifetime of the
instrument, and there will be no
need to redo the self-calibration.
Perform factory
reset
aXGFAC!
a+1<CR><LF>
Revert the device to default
factory settings. To fully revert
the device to factory settings,
the device must be power-cycled
after the factory reset command is
executed.