LX-80-15 10 Hz User Manual
24
LX-80-15 10 Hz Oceanographic Radar Sensor
8
Data Protocols
Geolux LX-80 level meter supports the following data protocols:
•
NMEA-like protocol on RS-232 interface that constantly outputs the detected current level
and averaged level, depending on the active settings for data filtering
•
Servicing protocol on RS-232 interface for configuring the unit
•
Request-response protocol (Modbus) on RS-485 interface that allows multiple units to be
used on a single RS-485 bus
•
SDI-12 protocol over SDI-12 interface
Support for additional protocols is available upon customer request.
8.1. NMEA Protocol (RS-232)
NMEA protocol is based on the standard protocol family widely used by navigation equipment. NMEA
protocol is sentence oriented and can send multiple sentences with different information. The sentence
content is designated by the starting keyword which is different for each sentence type. NMEA
sentences are terminated with the checksum which makes this protocol extremely reliable. NMEA
protocol is unidirectional; data is only transmitted from the level meter.
At RS-232 interface the device periodically outputs following data sentences:
Level measurement report
$LVX,L1,L2,T1,L3,L4,S1*CSUM <CR><LF>
firmware versions up to 2.3.2
$LVX,L1,L2,T1,L3,L4,S1,S2*CSUM<CR><LF>
firmware versions greater than 2.3.2
$LVX:
The keyword sent in the beginning of each detection report. This sentence is sent
whenever there is detected level.
L1:
The actual distance between the instrument and the water surface, as measured
by the instrument.
L2:
The average distance between the instrument and the water surface, as
measured by the instrument. This value is calculated by applying the averaging
filter to the data measurements. Filter parameters can be adjusted using the
Geolux Instrument Configurator application under device
Settings
.
T1:
The internal temperature of the instrument.
L3:
The actual water level measured by the instrument. The measured water level
depends on the measured distance between the instrument and the
water surface, and on the predefined instrument offset which can be adjusted
using the Geolux Instrument Configurator application under device
Settings
.
Содержание LX-80-15