LX-80-15 10 Hz User Manual
39
LX-80-15 10 Hz Oceanographic Radar Sensor
Fun
Register
Address
Data
Length
Data Range
Details
0X06
0x0015
2 bytes
2 printable characters
Serial number [0-1]
0x0016
2 bytes
2 printable characters
Serial number [2-3]
0x0017
2 bytes
2 printable characters
Serial number [4-5]
0x001C
2 bytes
0
→
No filter
1
→
IIR filter
2
→
Moving average filter
3
→
Median filter
4
→
Standard deviation filter
The filter type used for
statistical measurement
postprocessing
0x001D
2 bytes
0
→
mm
1
→
cm
2
→
m
3
→
ft
4
→
in
Level unit
0x0022
2 bytes
Sensor height
Sensor height above the
riverbed
0x0023
2 bytes
Staff gauge
Staff gauge measurement used
to indirectly determine sensor
height;
Sensor height = staff gauge +
current measured distance from
sensor to water
0x0024
2 bytes
0
→
Operating mode
1
→
Standby mode
Power management
0x0025
2 bytes
0
→
SDI-12 mode
1
→
Continuous scanning
Operation mode
0x0026
1
Recalibrate the instrument
0x0027
0 – max. distance
Save background, up to the
given distance
0x0028
2 bytes
0
→
Maximum peak
1
→
Last peak
Peak detector type
0x002C
2 bytes
0x0FAC
Factory reset
0x002D
2 bytes
0
→ All sentences are sent
1 → $WAV is not sent
2 → $ANG is not sent
3 → $WAV and $ANG are not sent
NMEA protocol flags
0x002E
2 bytes
0
→ Turned off
1 → Turned on
Force continuous calibration
0x0032
2 bytes
0
–3600
Wave analysis length