GM9907-L5
bulk scale controller user’s manual
- 28 -
.9
Calibration Fail, No Gain
Voltage Record
(
The
relative Gain Voltage is not
calibrated when the weight
is calibrated with None
weight
)
.10
Over&Under Pause
.11~.15
Reserved
0005
40006
Reserved
0006-0007 40007-40008
Weight
(
controllerdispl
ay weight
)
4 bytes, signed number (display
weight). Note: When the weight
overflows, the Controller displays
OFL, the weight value is fixed and
returns 0xFFFFFFFF
0008-0009 40009-40010
Precent Flowrate
Read only
:
Unit and decimal are read
in address 40010 and address 40011
0010
40011
Precent
FlowrateUnit
Read only
:
0
:
g/h
;
1
:
kg/h
;
2
:
t/h
;
3
:
lb/h
。
0011
40012
Precent
Flowratedecimal
Read only
:
0
:
0 bit
;
1
:
1 bit
;
2
:
2 bit
;
3
:
3 bit
;
4
:
4 bit
。
0012-0013 40013-40014
Version
Read only
,
eg
:
010000
0014-0015 40015-40016
Compile date
Read only
,
eg
:
180709
,
18-7-9
0016-0017 40017-40018
Edit date
Read only
,
eg
:
102010
,
10:20.10
0018~0099 40019~40100
reserved
0100
40101
in&out mode 0:Stock-in 1
:
Stock-out
0101-0102
40102-40103
Stock-in ACUM
(
0~999999999
)
0103-0104 40104-40105
in&out ACUM PCS
(
Read only
)
0105-0106 40106-40107
in&out ACUM weight
(
Read only
)
0107-0108 40108-40109
Total ACUM PCS
,
999999999
(
Read only
)
0109-0110 40110-40111
ACUM weight high 6 bit
(
Read only
)
0111-0112 40112-40113
ACUM weight low 9 bit
(
Read only
)
0113-0114 40114-40115
systemACUM
(
Read only
)
0115-0116 40116-40117
systemACUM weight high 6 bit
(
Read only
)
0117-0118 40118-40119
systemACUM weight low9bit
(
Read only
)