GM9907-L5
bulk scale controller user’s manual
- 14 -
Group ID
current formula
Motor Group
ID
This parameter used filling Motor Para. Group ID. Initial
value
:
0
,
range
:
0
~4
4.2
Weight parameter
In the menu interface, click the
【
Weight
】
to enter the current parameter to view and set
the owning parameter information
Items
Para
Discription
Basic
Paramet
er
Flowrate
Calculation
Window
Sampling time to caluate current flowrate value.
Initial value
:
3
,
range
:
1~6
Filling Ctrl
Mode
Combo Ctrl / Single Ctrl; Initial value
:
Combo Ctrl
Combo Ctrl
:
During
Coarse Flow fill, Co-F and Fi-F
filling port at the same time filling; Fi-F filling port
filling during Fine Flow.
Single Ctrl
:
Co-F large filling port filling; Fi-F small
filling port filling.
PWR-ON Zero
“On / Off” is optional
,
Initial value
:
OFF
.
when set to ON
:
the controller will automatically perform zero clearing
operation when the power is turned on (the weight inside the
scale bucket meets the zero range).
Manual DISC
Add To ACUM
“On / Off” is optional
,
set to ON
:
In stop state manual
discharge add to ACUM. Initial value
:
OFF
Result Hold
“On / Off” is optional
,
Initial value
:
OFF
Set to ON
:
result wait timer is finished, weight display
remain unchange
,
after finishing discharge, weight change.
OFF
:
Close Result Hold function.
Manual Clear
ACUM When
Start
“On / Off” is optional , Initial value
:
OFF
Set to ON
:
After stop or delivery is completed, need to
manually clear the total number of last shipments before
starting again
OFF
:
After stop or delivery is completed, controller will
automatically clear the ACUM total of the last delivery
Advance
d
Paramet
er
Digital Filter
(
STOP
)
1
:
filter effect is weakest
;
9
:
filter effect is strongest
Initial value
:
5
range
:
1
~
9
Filling Filter
Filter parameter in run
:
9
:
filter effect is weakest Initial
value
:
4
range:
1
~
9
Sample Rate
A/D
Sampling Rate
,
120
SPS
,
240
SPS
,
480
SPS
,
960
SPS
optional
,
Initial value
:
480