GM9907-L5
bulk scale controller user’s manual
- 21 -
ESC
:
02 30 31 52 53 30 53 47 2B 20 20 20 30 2E 38 37 31 30 0D 0A
Stop, stable, GS state
,
weight value is
0.87
.
Note
:
when controller receive error
,
back to negative respond
4.4.3
Response Mode-
2
Send format refer Response Mode
1
Response Mode
-2
:
function
code
Operation
object
data
description
R
T SP SP
None
Read total ACUM and ACUM weight
respond
:
4
bitACUM
;
10
bit decimal, Unit total ACUM
weight
R
T
None
Read total ACUM weight
respond
:
10
bit decimal total ACUM weight
R
T S U
None
Read in&out ACUM,total weight
respond
:
4
bit in&out times
;
1
0
bit decimal in&out total
weight
R
C
None
Read in&out ACUM, total weight
respond
:
4
bit in&out times
;
1
0
bit decimal in&out total
weight
◆
read ACUM, ACUM weight(
R T SP SP
)
:
02 30 31 52 54 20 20 32 39 0D 0A
respond
:
STX COM ID
R
T
ACUM
,
ACUM weight
Unit
CRC CR
LF
02H
30H 31H
52H 54H
4bit
,
10bit
2bit
CRC CR
LF
ESC
:
02 30 31 52 54 20 20 20 30 2C 20 20 20 20 20 30 2E 30 30 30 6C 62 35 37 0D
0A——
ACUM
0
;
ACUM weight
:
0.000
;
Unit
lb
(
g,kg,t,lb 2bits
)
◆
read ACUM weight(
R T
)
:
02 30 31 52 54 36 35 0D 0A
ESC
:
02 30 31 52 54 20 20 20 20 20 30 2E 30 30 30 36 33 0D 0A
◆
read in&out ACUM(
R T S U
)
:
02 30 31 52 54 53 55 33 33 0D 0A
ESC
:
02 30 31 52 54 20 20 20 32 2C 20 20 20 20 20 31 31 2E 33 38 36 36 0D 0A
◆
read in&out ACUM(
R C
)
:
02 30 31 52 43 34 38 0D 0A
ESC
:
02 30 31 52 43 20 20 20 31 2C 20 20 20 20 20 20 31 2E 37 38 33 35 0D 0A
4.4.4
Response Mode-
3
Send format refer Response Mode
1
;
controller set to Response Mode
3
:
function
code
Operation
object
data
description
R
T SP SP
None Read ACUM and ACUM weight
respond
:
4
bit ACUM
;
9
bit decimal ACUM weight