GM9907-L5
bulk scale controller user’s manual
- 44 -
port signal is valid.
O2
Stopped
When the controller is in the stop state, the output port
signal is valid.
O3
Co-Fill
Large outlet for controlling feeding mechanism. When
feeding, current weight lower than Target-Co-Feeding
Remains, this signal is valid.
O4
Fi-Fill
Small outlet for controlling feeding mechanism. When
feeding, current weight lower than Target-Free fall, this
signal is valid.
O5
Result Waiting
Used to indicate the end of the feeding process. This
signal is valid until the end of fine feed.
O6
Over/Under
This signal is valid when result waiting OVER or
UNDER.
O7
Alarm
When the controller displays an Alarm prompt, This
output is valid (eg Target is 0None start Alarm,
Over/Under Alarm, Zero Over range Alarm, Delivery
Complete, ONOFF gate timeout Alarm, ONOFF gate to
bit signal None effect Alarm...) .
O8
Stock-out Done
Controller Alarm Delivery done
,
output valid
O9
Last Feed
When this output is valid, this is the last feed
O10
DISC
The discharge door used to control the metering bucket.
O11
NearZero
This signal is valid when the current weight is less than
or equal to the set Near Zero.
O12
FILL Supplement
Used to control the feeding mechanism of the front end
of the packing scale, when the material hopper is 3
material bit control, the material bit input None effect,
the output is effective, when the material hopper bit
effective, the controller makes the output None effect;
When the material hopper for 2 material bit control,
feeding bit input None effect, the output is effective,
when the material hopper feeding bit is effective, the
controller makes the output None effect.
O13
Supplement Empty
Supplement OK or Supplement Empty the output is
valid when the input is selected and None is valid.
O14
Clogged(Out)
This output is valid if CLOG is defined and CLOG (I7)
is valid