GM9907-L5
bulk scale controller user’s manual
- 22 -
◆
read ACUM weight(
R T SP SP
)
:
02 30 31 52 54 20 20 32 39 0D 0A
respond
:
STX COM ID
R
T
ACUM
,
ACUM weight
CRC CR
LF
02H
30H 31H
52H 54H
4bit
,
9bit
CRC CR
LF
返 回
eg
:
02 30 31 52 54 20 20 20 34 2C 20 20 20 20 32 30 2E 33 31 32 39 0D
0A——
ACUM
4
;
ACUM weight
:
21.31
Note
:
1
)
When
c
ontroller actual accumulation in the system is greater than read range
,
read low
bit. ACUM read low 4bit
,
ACUM weight read low 9 bit
。
2)
Response Mode1-3 Protocols added to the company's earlier products format
4.4.5 Printing
Two serial communication interfaces of controller can be connected to serial printer
(RS232/RS485) and COM Para. The serial port Protocol is set to print, then the
corresponding serial port will have the printing function.
By setting the print format to 32 Columns and the print language to Chinese or English
。
Printing Description:
Under the parameter
【
Statistics-Recipe ACUM
】
, click "Print" to select the items to be
printed in the popup box, which can print total ACUM,present recipe ACUM data, all recipe
ACUM data and select recipe ACUM data for printing.
Under the parameter
【
Statistics-User ACUM
】
, click "Print" and select the items to be
printed in the box that pops up. You can print total ACUM, present user ACUM data, all
user ACUM data and select user ACUM data to print.
※
Note: If Protocol is not set to "print", "None" will be displayed when external input is
printed.
4.4.5.1 Auto print content
Set the serial port Protocol of COM para. to print and the automatic printing switch of
the print parameter to ON. The following contents will be printed automatically after each
weighing
English 24 Columns print format as below
:
Packing detail
Unit: kg
Recipe ID
:
3
ACUM:
result
----------------------------------
1
30.1
2
30.1
English 32 Columns print format as below
:
Packing detail
Unit: kg
Recipe ID:
3
ACUM
Target
result
----------------------------------------------
1
30.0
30.5
2
30.0
30.4